3.2 Nominal data

Motor

M4E068-DF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

fa

fa

Valid for approval /
standard

CE

CE

Speed (rpm) / min

-1

1360

1520

Power input / W

105

135

Current draw / A

0.52

0.6

Motor capacitor / µF

3

3

Capacitor voltage / VDB

400

400

Capacitor standard

S0 (CE)

S0 (CE)

Max. back pressure / Pa

60

70

Min. ambient
temperature / °C

-25

-25

Max. ambient
temperature / °C

65

65

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

4.1 kg

Size

330 mm

Motor size

68

Surface of rotor

Coated in black

Material of terminal box

PC / ABS plastic

Material of blades

Sheet steel, coated in black

Material of guard grille

Steel, coated in black plastic (RAL9005)

Number of blades

5

Direction of air flow

V

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP44; Depending on installation and
position as per EN 60034-5

Insulation class

"F"

Humidity (F) /
environmental
protection class (H)

H1

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensation
drainage holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Electrical connection

Terminal box; Via terminal box, capacitor
integrated and connected

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Motor capacitor
according to EN 60252-
1 in safety protection
class

S0

Product conforming
to standard

EN 60335-1; CE

Approval

CSA C22.2 no. 100; UL 1004-1

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

;

Use the device in accordance with its protection type.

Notes on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may vary during the production period.
Strength, dimensional stability and dimensional accuracy are not affected
by this.
The colour pigments of the paints used react perceptibly to UV light over
the course of time. This does not however have any influence on the
technical properties of the products. To prevent the formation of patches
and fading, the product is to be protected against UV radiation. Changes
in colour are not a reason for complaint and are not covered by the
warranty.

3.4 Mounting data

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

Any further mounting data required can be taken from the product
drawing or Section chapter 4.1 Connecting the mechanical system.

3.5 Transport and storage conditions

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 14634-5-9970 · ENG · Revision 206792 · Release 2019-11-18 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for S4E330-AP20-43

Page 1: ...d technical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety r...

Page 2: ...em machine wait until all parts have come to a standstill WARNING Rotating device Long hair dangling items of clothing jewellery and similar items can become entangled and be pulled into the device Ri...

Page 3: ...ce e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from the customer system to the fan Operation in medical equip...

Page 4: ...ve the unit mm 1 Direction of air flow V 2 Tightening torque 1 5 0 2 Nm 3 Cable diameter max 7 5 mm tightening torque 1 3 0 2 Nm Item no 14634 5 9970 ENG Revision 206792 Release 2019 11 18 Page 4 11 e...

Page 5: ...tection class I if protective earth is connected by customer Motor capacitor according to EN 60252 1 in safety protection class S0 Product conforming to standard EN 60335 1 CE Approval CSA C22 2 no 10...

Page 6: ...end is connected in a dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check that the data on the type plate matc...

Page 7: ...le routing No water may penetrate along the cable in the direction of the cable gland NOTE Damage caused by moisture penetration Moisture can penetrate into the terminal box if water is constantly pre...

Page 8: ...ions 4 4 Connection screen L U1 blue Z brown N U2 black PE green yellow Item no 14634 5 9970 ENG Revision 206792 Release 2019 11 18 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfing...

Page 9: ...to device by vibrations Bearing damage reduced service life The fan must operate free of vibrations throughout its speed control range Strong vibrations can result from improper handling imbalance re...

Page 10: ...basedcleaning agents Do not use any pointed or sharp edged objects for cleaning Completely remove any cleaning agents used Immediately switch off and replace the device if severe corrosion is apparen...

Page 11: ...ts could drop off during disassembly This can result in fatal or serious injury and material damage Secure components before unfastening to stop them falling 5 3 3 Component disposal The products are...

Reviews: