ebm-papst S4E330-AP20-43 Operating Instructions Manual Download Page 4

Operating instructions

S4E330-AP20-43

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Direction of air flow "V"

2

Tightening torque 1.5±0.2 Nm

3

Cable diameter: max. 7.5 mm, tightening torque 1.3±0.2 Nm

Item no. 14634-5-9970 · ENG · Revision 206792 · Release 2019-11-18 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for S4E330-AP20-43

Page 1: ...d technical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety r...

Page 2: ...em machine wait until all parts have come to a standstill WARNING Rotating device Long hair dangling items of clothing jewellery and similar items can become entangled and be pulled into the device Ri...

Page 3: ...ce e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from the customer system to the fan Operation in medical equip...

Page 4: ...ve the unit mm 1 Direction of air flow V 2 Tightening torque 1 5 0 2 Nm 3 Cable diameter max 7 5 mm tightening torque 1 3 0 2 Nm Item no 14634 5 9970 ENG Revision 206792 Release 2019 11 18 Page 4 11 e...

Page 5: ...tection class I if protective earth is connected by customer Motor capacitor according to EN 60252 1 in safety protection class S0 Product conforming to standard EN 60335 1 CE Approval CSA C22 2 no 10...

Page 6: ...end is connected in a dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check that the data on the type plate matc...

Page 7: ...le routing No water may penetrate along the cable in the direction of the cable gland NOTE Damage caused by moisture penetration Moisture can penetrate into the terminal box if water is constantly pre...

Page 8: ...ions 4 4 Connection screen L U1 blue Z brown N U2 black PE green yellow Item no 14634 5 9970 ENG Revision 206792 Release 2019 11 18 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfing...

Page 9: ...to device by vibrations Bearing damage reduced service life The fan must operate free of vibrations throughout its speed control range Strong vibrations can result from improper handling imbalance re...

Page 10: ...basedcleaning agents Do not use any pointed or sharp edged objects for cleaning Completely remove any cleaning agents used Immediately switch off and replace the device if severe corrosion is apparen...

Page 11: ...ts could drop off during disassembly This can result in fatal or serious injury and material damage Secure components before unfastening to stop them falling 5 3 3 Component disposal The products are...