CONNECTION AND COMMISSIONING

 

 
Connect mechanical parts 
 

 

CAUTION 
Risk of cutting/squashing when 
removing the product from the 
packaging and during mounting. 
 
Grasp the housing and lift the product 
carefully out of the packaging. Avoid 
impact. 

 

Wear safety boots and cut-resistant 
gloves. 

 

 
 
 

 

NOTE 
Risk of damage to electronic 
components. 
 

 

Use ESD protective equipment when 
mounting. 

 

Connect electrical parts 
 
Connect to the mains after installation. 
 

 

DANGER 
Compliance with the electrical 
installation regulations 
 

 

Observe the connection regulations 
that are valid in your country. (e.g. 
fusing, GFCI) 

 

 

CAUTION 
Electrical voltage 
The product is a built-in 
component and has no switch for 
disconnecting power.
 
 

 

Only connect the product to 
current circuits that can be 
switched off by a switch (all poles 
disconnected). When working on 
the product, secure the 
system/machine in which the 
product is installed against 
switching on again. 

 
 
NOTE 
Electromagnetic compatibility (EMC) may affect the system integration 
of the product due to interaction. 
 

 

Ensure the electromagnetic compatibility of the entire system. 

 

 
 
 
Voltage control 
 

 

Speed control via the supply voltage is 
only permitted within the stipulated 
supply voltage range. Speed control via 
PWM of the supply voltage is not 
permitted. 

 
Requirements: 
 
-  Before connecting the product, ensure that the supply voltage 

corresponds with the product voltage. 

-  Check whether the data on the nameplate corresponds with the 

interface data. 

 

 

Only use cables that are designed for 
the current on the nameplate and the 
corresponding ambient conditions. 
Ensure that the electrical interface data 
is adequately protected (mechanical). 

 
Find additional information in drawing or label. 
 

 

 

Plug connection 

Operation 

X1 Pin 1 

X1 Pin 2 

X1 Pin 3 

 
 
Check connections 
 
NOTE 
Connect product 
 
Check the product for visible damage and the operability of protective 
equipment before switching on. 
If damage is visible, do not start the product.

Summary of Contents for RV45-3/14

Page 1: ...es The following risk ratings are used in this operating manual to denote potential risk situations and important safety instructions DANGER This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed Observe this warning WARNING The dangerous situation can occur and can result in major or fatal injuries if the warning is ...

Page 2: ...ransported by the airflow The product can transport small parts in the airflow and catapult them out Ensure that there are no loose small parts in the intake and exhaust area Do not stand in the danger zone of the product CAUTION High risk of fire spreading Can cause fire to spread Never direct the airflow intake exhaust side at a potential source of fire Hot surface CAUTION High temperature at mo...

Page 3: ...ceed the permissible vibration load Operating the product close to inflammable materials or components Operating the product in an explosive atmosphere Use of the prouct as a safety component or for performing safety relevant functions Operating in medical devices with life sustaining or life saving function if not validated together with ebm papst Operating in non stationary systems e g railway v...

Page 4: ...ctly exposure to water must be avoided Pollution degree 1 according DIN EN 60664 1 There is either no pollution or it occurs only dry non conductive pollution The pollution has no negative impact Ambient conditions Permitted ambient temperature Transport and storage Operation 40 C 85 C 20 C 70 C Vibration and shock load The mechanical Vibration and Shock data for the product is available If the op...

Page 5: ...ch the product is installed against switching on again NOTE Electromagnetic compatibility EMC may affect the system integration of the product due to interaction Ensure the electromagnetic compatibility of the entire system Voltage control Speed control via the supply voltage is only permitted within the stipulated supply voltage range Speed control via PWM of the supply voltage is not permitted R...

Page 6: ...ge product Note If the device is not operated for a lengthy period in installed condition in a dry environment it is to be started up and operated at full speed for one hour at least every four months If the device is not operated for a lengthy period in installed condition in a damp environment e g outdoors it is to be started up and operated at full speed for at least three hours once a month to...

Page 7: ......

Reviews: