5
TECHNICAL DATA
Drawing, see annex
Technical description
Airflow direction
Air in axially, Air out radially
Rotating direction looking
at rotor
Counterclockwise
Nominal voltage
24 V
Current consumption
1.750 mA
Power consumption
42 W
Speed
39.200 1/min
Max. free-air flow
438 l/min
Mass
0,13 kg
Protection class
The product is intended for use in sheltered rooms with controlled
temperature and controlled humidity. Directly exposure to water must
be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive
pollution. The pollution has no negative impact.
Ambient conditions
Permitted ambient temperature
Transport and storage
Operation
-40 °C ... 85 °C
-20 °C ... 70 °C
Vibration and shock load
The mechanical Vibration and Shock data for the product is available.
If the operation of the product should take place in a sinusoidal
vibration containing environment or fixing the product on sinusoidal
vibrating surface, please contact our technical support.
Do not operate your product in the resonance range.