background image

 

 

page 1 of 7 

 

Operating manual 

 
RV45-3/14 
 
 
Product type, manufacturing date (calendar week/year of construction) 
and if required, conformity mark can be found on the nameplate on the 
product. 
Please provide us with the contents of the nameplate when making 
enquiries about the product. 
 
ebm-papst St.Georgen GmbH & Co. KG 
Hermann-Papst-Straße 1 
D - 78112 St.Georgen 
 
Phone: +49 (0) 7724 / 81-0 
Fax: +49 (0) 7724 / 81-1309 
 
[email protected] 
www.ebmpapst.com 
 
As per: 25.05.2021 
Version: 1 0 
Article number: 9593505001 
 
 

Original operating manual 

 

INDEX 

1

 

SAFETY REGULATIONS AND INFORMATION 

1

 

2

 

INTENDED USE 

3

 

3

 

LIMITATIONS OF PERMITTED USE 

3

 

4

 

NOT INTENDED USE 

3

 

5

 

TECHNICAL DATA 

4

 

6

 

CONNECTION AND COMMISSIONING 

5

 

7

 

FAULTS, POSSIBLE CAUSES AND REMEDIES 

6

 

 
 

1  SAFETY REGULATIONS AND INFORMATION

 

 
Read the operating manual carefully before commencing work at the 
product. Pay attention to the following warnings to avoid risk to 
persons or malfunctioning. 
This operating manual is an integral part of the product. 
In the event of resale or change of ownership the operating manual 
must accompany the product. This operating manual may be copied 
and provided as information on potential risks and their avoidance. 
 
Hazard classification of warning notices 
 
The following risk ratings are used in this operating manual to denote 
potential risk situations and important safety instructions: 

 

 

DANGER 
This is a potentially dangerous situation 
and warns of an impending health risk 
or risk of fatal injury if this warning is 
not observed. Observe this warning. 

 

WARNING 
The dangerous situation can occur and 
can result in major or fatal injuries if the 
warning is not observed. Work with 
extreme care. 

 

CAUTION 
The dangerous situation can occur and 
can result in minor injuries or damage 
to property if the warning is not 
observed. 

 

NOTE 
A potentially dangerous situation can 
occur and results in damage to 
property if not avoided. 

 
Qualification of personnel 
 
Only skilled electricians are permitted to install the product, to carry out 
the test run and to work at the electrical unit. 
Only instructed and authorized skilled personnel are permitted to 
transport, unpack, operate and service the product. 
 
Basic safety regulations 
 
Safety risks related to the product must be reassessed after installing 
in the final device. 
The operating manual was developed in accordance with European 
market requirements and may need adapting to the market 
requirements of the country in question. 
 
When working at the product, observe the following: 
 

 

Do not make any changes to the product. 

 

 

WARNING 
Impermissible high load 

 

 

Stop the product immediately after 
impermissible loading (e.g. impact, 
heat, overvoltage). 

 
 

Summary of Contents for RV45-3/14

Page 1: ...es The following risk ratings are used in this operating manual to denote potential risk situations and important safety instructions DANGER This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed Observe this warning WARNING The dangerous situation can occur and can result in major or fatal injuries if the warning is ...

Page 2: ...ransported by the airflow The product can transport small parts in the airflow and catapult them out Ensure that there are no loose small parts in the intake and exhaust area Do not stand in the danger zone of the product CAUTION High risk of fire spreading Can cause fire to spread Never direct the airflow intake exhaust side at a potential source of fire Hot surface CAUTION High temperature at mo...

Page 3: ...ceed the permissible vibration load Operating the product close to inflammable materials or components Operating the product in an explosive atmosphere Use of the prouct as a safety component or for performing safety relevant functions Operating in medical devices with life sustaining or life saving function if not validated together with ebm papst Operating in non stationary systems e g railway v...

Page 4: ...ctly exposure to water must be avoided Pollution degree 1 according DIN EN 60664 1 There is either no pollution or it occurs only dry non conductive pollution The pollution has no negative impact Ambient conditions Permitted ambient temperature Transport and storage Operation 40 C 85 C 20 C 70 C Vibration and shock load The mechanical Vibration and Shock data for the product is available If the op...

Page 5: ...ch the product is installed against switching on again NOTE Electromagnetic compatibility EMC may affect the system integration of the product due to interaction Ensure the electromagnetic compatibility of the entire system Voltage control Speed control via the supply voltage is only permitted within the stipulated supply voltage range Speed control via PWM of the supply voltage is not permitted R...

Page 6: ...ge product Note If the device is not operated for a lengthy period in installed condition in a dry environment it is to be started up and operated at full speed for one hour at least every four months If the device is not operated for a lengthy period in installed condition in a damp environment e g outdoors it is to be started up and operated at full speed for at least three hours once a month to...

Page 7: ......

Reviews: