3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Connection line PVC 9G AWG20, 9x brass lead tips crimped

2

Accessory part: Inlet nozzle 31050-2-4013, not included in the standard scope of delivery

3

Depth of screw max. 5 mm

Item no. 11501-5-9970 · Revision 73571 · Release 2011-04-13 · Page 4 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R4D310-AR18-01

Page 1: ...he electrical system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules...

Page 2: ...ll WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while work...

Page 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Page 4: ...line PVC 9G AWG20 9x brass lead tips crimped 2 Accessory part Inlet nozzle 31050 2 4013 not included in the standard scope of delivery 3 Depth of screw max 5 mm Item no 11501 5 9970 Revision 73571 Re...

Page 5: ...ischarge holes Rotor side Operation mode S1 Motor bearing Ball bearing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP brought out...

Page 6: ...n follow the basic principles in accordance with EN 61800 5 1 The protective earth must have a cross section equal to or greater than the outer conductor cross section We recommend the use of 105 C ca...

Page 7: ...Star connection L1 black L2 blue L3 brown U1 black V1 blue W1 brown U2 green V2 white W2 yellow TOP 2xgrey PE green yellow Item no 11501 5 9970 Revision 73571 Release 2011 04 13 Page 7 9 ebm papst Mu...

Page 8: ...er failure Danger of injury Keep out of the danger zone of the device When working on the device switch off the mains supply voltage and secure the latter from being switched on again Wait until the d...

Page 9: ...ing Visual inspection At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth connection Visual in...