![ebm-papst R3G500-AG10-13 Operating Instructions Manual Download Page 4](http://html1.mh-extra.com/html/ebm-papst/r3g500-ag10-13/r3g500-ag10-13_operating-instructions-manual_2353258004.webp)
Operating instructions
R3G500-AG10-13
Translation of the original operating instructions
3. TECHNICAL DATA
3.1 Product drawing
All measures have the unit mm.
1
Cable diameter: min. 4 mm, max. 10 mm, tightening torque: 4±0.6 Nm
2
Accessory part: Inlet nozzle 63072-2-4013, not included in the standard scope of delivery.
3
Depth of screw max. 25 mm
4
Tightening torque 3.5±0.5 Nm
Item no. 50489-5-9970 · Revision 82539 · Release 2014-05-08 · Page 4 / 12