background image

Operating instructions

R3G355-AM08-32

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable PVC AWG16, 4x crimped ferrules

2

Accessory part: inlet ring 35560-2-4013 not included in scope of delivery

3

Clearance for screw 12 - 14 mm

Item no. 51826-5-9970 · ENU · Change 89187 · Approved 2016-04-14 · Page 4 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R3G355-AM08-32

Page 1: ...ly qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic...

Page 2: ...the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and...

Page 3: ...with all protective devices Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an...

Page 4: ...able PVC AWG16 4x crimped ferrules 2 Accessory part inlet ring 35560 2 4013 not included in scope of delivery 3 Clearance for screw 12 14 mm Item no 51826 5 9970 ENU Change 89187 Approved 2016 04 14 P...

Page 5: ...etermined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weight 4 9 kg Fan size 355 mm Rotor surface Painted black Electronics housing material Die ca...

Page 6: ...the cable can damage the device Make sure the end of the cable is connected in a dry environment Operate the device with a safely isolated power supply 4 2 1 Requirements Check whether the data on the...

Page 7: ...pply 48 VDC maximum ripple 3 5 1 2 PWM yellow PWM level 2 8 V 20 V cable break detection 1 3 Tach white Tach output open col 3 pulses per revolution Isink max 10 mA 1 4 GND blue Reference ground Item...

Page 8: ...e terminals and connections even with device switched off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device CAUTION If control voltage or a stored...

Page 9: ...cific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassembly...

Reviews: