background image

Operating instructions

R3G225-RE07-01

Translation of the original operating instructions

4.4 Connection diagram

Drawing preliminary!

No.

Conn.

Designation

Color

Function/assignment

CON 10 L

black

Power supply 230 VAC, 50-60 Hz, see nameplate for voltage range

CON 11 N

blue

Neutral conductor

CON 12 PE

green/
yellow

Protective earth

CON 70 SL

brown

Speed selection: switch open speed 1; switch closed speed 2

Item no. 51187-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 7 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R3G225-RE07-01

Page 1: ...ted maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform wo...

Page 2: ...he user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device R...

Page 3: ...ve devices Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e...

Page 4: ...t ring 96358 2 4013 not included in scope of delivery 2 Cable PVC 4G 0 5 mm 4x crimped splices 3 Max clearance for screw 5 mm 4 Max clearance for screw 10 mm Item no 51187 5 9970 ENU Change 89188 Appr...

Page 5: ...t setup 3 4 Technical description Weight 1 7 kg Fan size 225 mm Rotor surface Thick film passivated Electronics housing material Die cast aluminum Impeller material PA plastic Number of blades 7 Direc...

Page 6: ...ower supply matches the device voltage Only use cables designed for the current level indicated on the nameplate For determining the cross section note the sizing criteria according to EN 61800 5 1 Th...

Page 7: ...230 VAC 50 60 Hz see nameplate for voltage range CON 11 N blue Neutral conductor CON 12 PE green yellow Protective earth CON 70 SL brown Speed selection switch open speed 1 switch closed speed 2 Item...

Page 8: ...the blockage is removed the motor restarts automatically 6 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or r...

Page 9: ...he basis of German standards Right from the development stage ecological design technical safety and health protection are fixed criteria The following section contains recommendations for ecological...

Page 10: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 51187 5 9970 ENU Change 89188 Approved 2016 04 18 Page 10 10 ebm papst Mulfinge...