3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Accessory part: Inlet ring 96358-2-4013 not included in scope of delivery.

2

Max. clearance for screw 5 mm

3

Cable PFA AWG20
4x splice

Item no. 10275-5-9970 · ENU · Change 238316 · Approved 2021-10-14 · Page 4 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2E225-BD40-28

Page 1: ...d otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electri...

Page 2: ...efore working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pul...

Page 3: ...ing the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer...

Page 4: ...1 Accessory part Inlet ring 96358 2 4013 not included in scope of delivery 2 Max clearance for screw 5 mm 3 Cable PFA AWG20 4x splice Item no 10275 5 9970 ENU Change 238316 Approved 2021 10 14 Page 4...

Page 5: ...ing instructions All dimensions in mm Inlet ring 96358 2 4013 Item no 10275 5 9970 ENU Change 238316 Approved 2021 10 14 Page 5 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49...

Page 6: ...ic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance...

Page 7: ...re the end of the cable is connected in a dry environment Only connect the device to circuits that can be switched off with an all pole disconnection switch 4 2 1 Requirements Check whether the inform...

Page 8: ...st connect the PE protective earth Connect the cables according to your application When doing so observe Chapter 4 4 Connection diagram Item no 10275 5 9970 ENU Change 238316 Approved 2021 10 14 Page...

Page 9: ...ctions 4 4 Connection diagram U1 blue Z brown U2 black PE green yellow Item no 10275 5 9970 ENU Change 238316 Approved 2021 10 14 Page 9 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen...

Page 10: ...AINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with d...

Page 11: ...astening the protective earth terminal Visual inspection At least every 6 months Fasten Insulation of cables for damage Visual inspection At least every 6 months Replace cables Impeller for wear depos...

Page 12: ...ires are made of similar materials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulators used in the terminal box Power cables Cables for i...

Reviews: