background image

Operating instructions

R2E180-CG82-01

Translation of the original operating instructions

2. INTENDED USE

The device is exclusively designed as a built-in device for conveying
air according to its technical data.
Any other usage above and beyond this does not conform with the
intended purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical
and thermal stresses that can arise from this product. This applies for the
entire service life of the equipment in which this product is installed.

Intended use also includes

Conveying air at an ambient air pressure between 800 mbar and
1050 mbar.

Using the device within the permitted ambient temperature range; see
Chapter 3.5 Transport and storage conditions and
Chapter 3.2 Nominal data.

Operating the device with all protective devices.

Following the operating instructions.

Using the device only for conveying exhaust from exhaust blowers
for wood-based fuels.

Using the device within the permitted ambient temperature range; see
Chapter 3.5 Transport and storage conditions and
Chapter 3.2 Nominal data.

Using the device only in stationary systems.

Commissioning the built-in component only after installation in the
customer equipment.

Operating the device with all protective devices.

Following the operating instructions.

Improper use

In particular, operating the device in the following ways is prohibited and
could be hazardous:

Operating the device in an unbalanced state, e.g. due to dirt deposits
or ice formation.

Resonant operation, operation with severe vibration. This also
includes vibration transmitted to the fan from the customer installation.

Conveying highly corrosive air, e.g. salt spray. Exception: devices
designed for salt spray and correspondingly protected.

Operation with external vibrations.

Operating the device in an explosive atmosphere.

Operation in medical equipment with a life-sustaining or life-support
function.

Contact with materials that could damage blower parts, e.g. liquids
during cleaning.

Operation with completely or partially disassembled or manipulated
protective devices.

Using the device as a safety component or to perform safety-related
functions.

In addition, all applications not listed among the intended uses.

Item no. 11125-5-9970 · ENU · Change 94079 · Approved 2017-10-26 · Page 3 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for R2E180-CG82-01

Page 1: ...ed by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installati...

Page 2: ...coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating de...

Page 3: ...stationary systems Commissioning the built in component only after installation in the customer equipment Operating the device with all protective devices Following the operating instructions Imprope...

Page 4: ...ing All dimensions in mm 1 Cable silicone 4G 0 5 mm 4x crimped splices 2 Cable Raychem AWG24 3x crimped splices Item no 11125 5 9970 ENU Change 94079 Approved 2017 10 26 Page 4 10 ebm papst Mulfingen...

Page 5: ...th standards EN 60335 1 CE Approval EAC With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions...

Page 6: ...irements Check whether the information on the nameplate matches the connection data If the motor run capacitor was not installed by ebm papst check whether the information on the motor run capacitor m...

Page 7: ...has external leads Connect the cables according to your application When doing so observe Chapter 4 5 Connection diagram Item no 11125 5 9970 ENU Change 94079 Approved 2017 10 26 Page 7 10 ebm papst M...

Page 8: ...diagram U1 blue Z brown U2 black PE green yellow 2 Hall IC circuit 2 1 Hall IC 2 2 red 5 V 2 3 white out 2 4 black 0 V Item no 11125 5 9970 ENU Change 94079 Approved 2017 10 26 Page 8 10 ebm papst Mul...

Page 9: ...MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with...

Page 10: ...isposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassembly Disassembly of the product must be performed...