3.2 Nominal data

Motor

M4Q045-CA

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Method of obtaining
data

me

me

Valid for approval/
standard

UL 2111

UL 2111

Speed (rpm) / min

-1

1300

1550

Power consumption / W

36

34

Power output / W

10

9

Current draw / A

0.25

0.22

Min. ambient
temperature / °C

-30

-30

Max. ambient
temperature / °C

40

40

Starting current / A

0.32

0.3

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1.1 kg

Motor size

45

Bearing shield material

Die-cast aluminum

Direction of rotation

Counterclockwise, viewed toward rotor

Degree of protection

IP42

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H1

Installation position

Shaft horizontal

Condensation
drainage holes

None

Mode

S1

Motor bearing

Calotte bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Motor protection

Impedance protection

with cable

Lateral

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 60335-1; CE

Approval

CSA C22.2 No. 77; EAC; UL 1004-2

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

For screw clearance, see Chapter 3.1 Product drawing

Strength class of
screws

8.8

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 11281-5-9970 · ENU · Change 202174 · Approved 2018-12-28 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for M4Q045-CA25-04

Page 1: ...d maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work...

Page 2: ...ny loose fitting or dangling clothing or jewelry while working on rotating parts Protect long hair with a cap WARNING Ejected parts If the motor is operated with attached fan blades missing protective...

Page 3: ...with severe vibration oscillation This also includes vibration transmitted to the motor from the customer installation Operation in medical equipment with a life sustaining or life support function Co...

Page 4: ...ousing or guard grille 2 3 Nm 3 Tightening torque for screw for fastening fan impeller 1 4 Nm 4 Tightening torque for nut for fastening mounting bracket 2 3 Nm 5 Direction of rotation counterclockwise...

Page 5: ...he device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Information on su...

Page 6: ...er supply matches the device voltage Only use cables designed for the current level indicated on the nameplate For determining the cross section note the sizing criteria according to EN 61800 5 1 The...

Page 7: ...instructions 4 4 Connection diagram L blue PE green yellow N brown Item no 11281 5 9970 ENU Change 202174 Approved 2018 12 28 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phon...

Page 8: ...to move the bearings and allow any condensate that may have ingressed to evaporate Malfunction fault Possible cause Possible remedy Rotor not running smoothly Imbalance in rotating parts Clean the dev...

Page 9: ...etallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plast...

Reviews: