background image

Operating instructions

M4Q045-CA25-04

Translation of the original operating instructions

2. INTENDED USE

The device is designed exclusively for use as a drive motor.
Any other usage above and beyond this does not conform with the
intended purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical
and thermal stresses that can arise from this product. This applies for the
entire service life of the equipment in which this product is installed.

Intended use also includes

Using the device within the permitted ambient temperature range; see
Chapter 3.5 Transport and storage conditions and
Chapter 3.2 Nominal data.

Operating the device with all protective devices.

Following the operating instructions.

Improper use

In particular, operating the device in the following ways is prohibited and
could be hazardous:

Resonant operation, operation with severe vibration/oscillation. This
also includes vibration transmitted to the motor from the customer
installation.

Operation in medical equipment with a life-sustaining or life-support
function.

Conveying solids in the flow medium.

Painting the device

Connections (e.g. screws) coming loose during operation.

Conveying air that contains abrasive particles.

Conveying highly corrosive air, e.g. salt spray. Exception: devices
designed for salt spray and correspondingly protected.

Conveying air with high dust content, e.g. suctioning off sawdust.

Operating the device close to flammable materials or components.

Operating the device in an explosive atmosphere.

Using the device as a safety component or to perform safety-related
functions.

Operation with completely or partially disassembled or manipulated
protective devices.

In addition, all applications not listed among the intended uses.

Item no. 11281-5-9970 · ENU · Change 202174 · Approved 2018-12-28 · Page 3 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for M4Q045-CA25-04

Page 1: ...d maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work...

Page 2: ...ny loose fitting or dangling clothing or jewelry while working on rotating parts Protect long hair with a cap WARNING Ejected parts If the motor is operated with attached fan blades missing protective...

Page 3: ...with severe vibration oscillation This also includes vibration transmitted to the motor from the customer installation Operation in medical equipment with a life sustaining or life support function Co...

Page 4: ...ousing or guard grille 2 3 Nm 3 Tightening torque for screw for fastening fan impeller 1 4 Nm 4 Tightening torque for nut for fastening mounting bracket 2 3 Nm 5 Direction of rotation counterclockwise...

Page 5: ...he device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Information on su...

Page 6: ...er supply matches the device voltage Only use cables designed for the current level indicated on the nameplate For determining the cross section note the sizing criteria according to EN 61800 5 1 The...

Page 7: ...instructions 4 4 Connection diagram L blue PE green yellow N brown Item no 11281 5 9970 ENU Change 202174 Approved 2018 12 28 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phon...

Page 8: ...to move the bearings and allow any condensate that may have ingressed to evaporate Malfunction fault Possible cause Possible remedy Rotor not running smoothly Imbalance in rotating parts Clean the dev...

Page 9: ...etallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron Aluminum Non ferrous metal e g motor windings Plast...