Operating instructions
K3G630-AP01-90
`
II 2G Ex db eb ib IIB T3 Gb
IBExU14ATEX1122 X /05
`
Translation of the original operating instructions
54007-4-8670
4. TECHNICAL DATA
4.1 Product drawing
All dimensions in mm.
1
Inlet ring with pressure tap
2
Mounting position for vibration-absorbing elements
3
Cable diameter min. 10 mm, max. 16 mm, tightening torque 6 ± 0.6 Nm; standard value depending on cable
4
Screw plug M20 x 1.5
5
Cable diameter min. 10 mm, max. 14 mm, tightening torque 6 ± 0.6 Nm; standard value depending on cable
6
Terminal box fastening screws, tightening torque 3.5 ± 0.5 Nm
7
Ground connection point M8 (functional ground for electrostatic discharge, no protective earth), do not unfasten the nut provided, contact is
established by way of another nut.
8
Axial gap dimension
9
Radial gap dimension
10
Additional nameplate and warning sticker in Russian
11
Fastening points for the optionally available guard grill (78138-2-4039 (guard grill); 79630-2-4039 (mesh guard grill))
Item no. 54007-5-9970 · ENU · Change 272968 · Approved 2022-11-23 · Page 6 / 18