ebm-papst K3G400-RP45-25 Operating Instructions Manual Download Page 3

Operating instructions

K3G400-RP45-25

Translation of the original operating instructions

;

Even devices explicitly intended for outdoor use are to be stored as
described prior to commissioning.

;

Maintain the storage temperature, see
Chapter 3.6 Transport and storage conditions.

2. INTENDED USE

The device is exclusively designed as a built-in device for conveying
air according to its technical data.
Any other usage above and beyond this does not conform with the
intended purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical
and thermal stresses that can arise from this product. This applies for the
entire service life of the equipment in which this product is installed.

Intended use also includes

Use of the device in stationary systems only.

Performance of all maintenance work.

Conveying air at an ambient air pressure between 800 mbar and
1050 mbar.

Using the device within the permitted ambient temperature range; see
Chapter 3.6 Transport and storage conditions and
Chapter 3.2 Nominal data.

Operating the device with all protective devices.

Following the operating instructions.

Improper use

In particular, operating the device in the following ways is prohibited and
could be hazardous:

Operating the device in an unbalanced state, e.g. due to dirt deposits
or ice formation.

Resonant operation, operation with severe vibration. This also
includes vibration transmitted to the fan from the customer installation.

Operation in medical equipment with a life-sustaining or life-support
function.

Conveying solids in the flow medium.

Painting the device

Connections (e.g. screws) coming loose during operation.

Conveying air that contains abrasive particles.

Conveying highly corrosive air, e.g. salt spray. Exception: devices
designed for salt spray and correspondingly protected.

Conveying air with high dust content, e.g. suctioning off sawdust.

Operating the device close to flammable materials or components.

Operating the device in an explosive atmosphere.

Using the device as a safety component or to perform safety-related
functions.

Operation with completely or partially disassembled or manipulated
protective devices.

In addition, all applications not listed among the intended uses.

Item no. 57388-5-9970 · ENU · Change 214130 · Approved 2020-07-14 · Page 3 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for K3G400-RP45-25

Page 1: ...ized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards assoc...

Page 2: ...ntact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and...

Page 3: ...ating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ic...

Page 4: ...ox 2 Connector housing 3 pole GST18 3 Wieland 92 032 9058 1 2 1 N 2 2 PE 2 3 L 3 8 pole connector housing TE 100616 2 4 8 pole connector housing TE 100616 2 Item no 57388 5 9970 ENU Change 214130 Appr...

Page 5: ...tandardized measurement setup 3 4 Technical description Weight 10 06 kg Size 400 mm Motor size 84 Rotor surface Painted black Electronics housing material Die cast aluminum Impeller material PP plasti...

Page 6: ...g hold of the frame Never subject to any impact Wear safety shoes and cut resistant safety gloves CAUTION Heavy load when unpacking device Risk of physical injury such as back injuries Two people shou...

Page 7: ...that the minimum cable cross section is at least AWG 26 0 13 mm 4 2 2 Reactive currents Because of the EMC filter integrated for compliance with EMC limits interference emission and immunity to inter...

Page 8: ...US RSA KL2 KL3 2 RSB RS 485 interface for MODBUS RSB KL2 KL3 3 RSA RS 485 interface for MODBUS RSA KL2 KL3 4 Bridge KL2 KL3 KL2 KL3 5 Bridge KL2 KL3 KL2 KL3 6 RSB RS 485 interface for MODBUS RSB KL2 K...

Page 9: ...n order to obtain a complete picture of the vibrations occurring in the application see Chapter 6 Maintenance malfunctions possible causes and remedies 4 7 Switching off the device Disconnect the devi...

Page 10: ...fe check the fans regularly for proper operation and soiling The frequency of checking is to be adapted accordingly depending on the degree of soiling DANGER Risk of injury from rotating fan Only clea...

Page 11: ...s 6 4 1 Country specific legal requirements NOTE Country specific legal requirements Always observe the applicable country specific legal regulations with regard to the disposal of products or waste o...

Reviews: