background image

Operating instructions

K3G280-PR04-I2

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Connection line PVC AWG18, 5x crimped core-end sleeves

2

Connection line PVC AWG22, 5x crimped core-end sleeves

3

Inlet nozzle 28004-2-4013 with pressure tap (k-factor: 77)

4

Mounting for inlet nozzle and FlowGrid

Item no. 54426-5-9970 · ENG · Revision 90170 · Release 2016-07-14 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for K3G280-PR04-I2

Page 1: ...carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluated once it is ins...

Page 2: ...ystem machine wait until all parts have come to a standstill WARNING Rotating device Long hair dangling items of clothing jewellery and similar items can become entangled and be pulled into the device...

Page 3: ...ding the operating instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits...

Page 4: ...imped core end sleeves 2 Connection line PVC AWG22 5x crimped core end sleeves 3 Inlet nozzle 28004 2 4013 with pressure tap k factor 77 4 Mounting for inlet nozzle and FlowGrid Item no 54426 5 9970 E...

Page 5: ...ion with optimum efficiency The ErP data is determined using a motor impeller combination in a standardised measurement configuration 3 4 Technical features Mass 9 1 kg Size 280 mm Surface of rotor Co...

Page 6: ...shoes and cut resistant safety gloves NOTE Damage to device from vibration Bearing damage reduced service life Forces or impermissibly high vibration levels must not be transmitted to the fan from sy...

Page 7: ...on the device The protective earth terminal is located on the housing and provided with a protective earth symbol and a hole 4 2 2 Idle current Because of the EMC filter integrated for compliance with...

Page 8: ...atus contact common connection contact rating 250 VAC 2A AC1 min 10 mA basic insulation on mains side and reinforced insulation on control interface side 2 8 0 10V yellow Analogue input 1 set value 0...

Page 9: ...ct the device from the supply voltage When disconnecting be sure to disconnect the earth wire connection last 5 INTEGRATED PROTECTIVE FUNCTIONS The integrated protective functions cause the motor to s...

Page 10: ...st NOTE High voltage test The integrated EMC filter contains Y capacitors Therefore the trigger current is exceeded when AC testing voltage is applied Test the device with DC voltage when you carry ou...

Page 11: ...ts could drop off during disassembly This can result in fatal or serious injury and material damage Secure components before unfastening to stop them falling 6 4 3 Component disposal The products are...