3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Connection line, halogen-free, railway application EN 45545, 5G 1.0 mm²
5x core-end sleeve

2

Connection line, halogen-free, railway application EN 45545, 3x 0.33 mm²
3x core-end sleeve

Item no. 56040-5-9970 · ENG · Revision 260973 · Release 2022-07-15 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for G3G225-CD29-72

Page 1: ...orised technical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic saf...

Page 2: ...fan is installed appropriate shielding measures have to be taken by the user NOTE Electrical or electromagnetic interferences after integrating the device in installations on the customer s side Veri...

Page 3: ...cularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that a...

Page 4: ...halogen free railway application EN 45545 5G 1 0 mm 5x core end sleeve 2 Connection line halogen free railway application EN 45545 3x 0 33 mm 3x core end sleeve Item no 56040 5 9970 ENG Revision 2609...

Page 5: ...e 2 2a motors completely integrated into a product 3 4 Technical features Mass 8 55 kg Size 225 mm Motor size 84 Surface of rotor Coated in black Material of electronics housing Die cast aluminium Mat...

Page 6: ...0 C between mains wire and protective earth connection after switching of the supply when switching multiple devices in parallel Electric shock risk of injury Make sure that sufficient protection agai...

Page 7: ...aracteristic K 4 2 4 Basic insulation of the alarm relay As the alarm relay only has basic insulation for TN TT systems and function insulation for systems with external conductor earthing with respec...

Page 8: ...inal operating instructions 4 5 Connection screen Item no 56040 5 9970 ENG Revision 260973 Release 2022 07 15 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938 81...

Page 9: ...e sure to disconnect the earth wire connection last 5 INTEGRATED PROTECTIVE FUNCTIONS The integrated protective functions cause the motor to switch off automatically in case of faults described in the...

Page 10: ...sedcleaning agents Do not use any pointed or sharp edged objects for cleaning Completely remove any cleaning agents used Immediately switch off and replace the device if severe corrosion is apparent a...

Page 11: ...ts could drop off during disassembly This can result in fatal or serious injury and material damage Secure components before unfastening to stop them falling 6 3 3 Component disposal The products are...

Reviews: