1.12 Storage
Operating instructions
2. PROPER USE
;
Store the device, partially or fully assembled, in a dry and
weatherproof manner in the original packing in a clean environment.
;
Protect the device from environmental impacts and dirt until the final
installation.
;
We recommend storing the device for a maximum up to one year to
guarantee proper operation and longest possible service life.
;
Even devices explicitly suited for outdoor use are to be stored as
described prior to being commissioned.
;
Maintain the storage temperature, see
chapter 3.5 Transport and storage conditions.
1.13 Disposal
When disposing of the device, please comply with all relevant
requirements and regulations applicable in your country.
The device is exclusively designed as a built-in device for moving air
and gases according to its technical data.
Any other or secondary use is deemed improper and constitutes a
misuse of the device.
Installations on the customer's side must meet the mechanical, thermal
and service life-related stresses that can occur.
Proper use also includes:
●
Moving a gas/air mixture in gas burners with H gas, L gas
and liquid gas according to gas family 2 and 3 in accordance with
the German DVGW (German Technical and Scientific Association
for Gas and Water),
worksheet 260, in a concentration of approx. 90 % air and 10 %
gas, integrated into
an overall system which is designed specifically for operation with
this gas type.
●
Moving air with a density ranging from 0.9 to 1.2 kg/m
і
.
●
Minding the operating instructions.
●
Using the device in accordance with the permitted ambient
temperature, see chapter 3.5 Transport and storage conditions and
chapter .
●
Only using the device in stationary systems.
●
Installing the device into an overall system for moving air/gas
mixtures.
●
Commissioning the built-in component only after installation in
the customer unit.
●
Operating the device with all protective features in place.
Improper use
Using the device in the following ways is particularly prohibited and
may cause hazards:
●
Operating the device with an imbalance, e.g. caused by dirt deposits
or icing.
●
Moving a medium that contains abrasive particles.
●
Moving a highly corrosive medium.
●
Moving a medium that contains dust pollution, e.g.
suctioning off saw dust.
●
Operating the gas blower in an environment that contains
flammable gases or dust or combustible solids or fluids.
●
Moving an air/gas mixture outside an overall system
that fulfils the requirements described above.
●
Using the blower as a safety component or for taking
on safety-related functions.
●
Operation in medical equipment with a life-sustaining or lifesaving
function.
●
Contact with materials that could damage blower parts, e.g. liquids
during cleaning.
●
Operation with completely or partially disassembled or modified
protective features.
●
Exposure to radiation which could damage blower parts, e.g. strong
UV radiation.
●
Operation with external vibrations.
●
Operating the device in an explosive atmosphere.
●
Operation with completely or partially disassembled or modified
protective features.