![ebm-papst D3G146-LV13-01 Operating Instructions Manual Download Page 8](http://html.mh-extra.com/html/ebm-papst/d3g146-lv13-01/d3g146-lv13-01_operating-instructions-manual_529183008.webp)
Operating instructions
D3G146-LV13-01
Translation of the original operating instructions
4.4 Connection diagram
Drawing preliminary!
No.
Conn.
Designation
Color
Function/assignment
CON10
10.1
PE
green/
yellow
Protective earth
CON10
10.2
L
black
Power supply 230 VAC, 50-60 Hz, see nameplate for voltage range
CON10
10.3
N
blue
Neutral conductor
CON11
11.1
10 V/max. 1.1
mA
red
Voltage output 10 V, 1.1 mA, electrically isolated, not short-circuit-proof
CON11
11.2
Tach
white
Tach output: Open collector, 1 pulse per revolution, electrically isolated, Isink max = 10 mA
CON11
11.3
0-10 V PWM
yellow
Control input 0-10 V or PWM, electrically isolated
CON11
11.4
GND
blue
GND connection for control interface
Item no. 51144-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 8 / 11