Operating instructions

D1G146-LV03-06

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Connection line PVC AWG20
3-pole connector housing TE 2178473-3, 3x plug pin TE 926887-1

1.1

FE (green/yellow)

1.2

N (blue)

1.3

L (black)

2

Connection line PVC AWG20
4-pole connector housing TE 350779-5, 3x plug pin TE 926887-1

2.1

not used

2.2

GND (blue)

2.3

PWM (yellow)

2.4

Fan good / fan bad (white)

Item no. 54195-5-9970 · ENG · Revision 225511 · Release 2022-01-11 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for D1G146-LV03-06

Page 1: ...ly authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety haza...

Page 2: ...cal or electromagnetic interferences after integrating the device in installations on the customer s side Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device B...

Page 3: ...and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from...

Page 4: ...pin TE 926887 1 1 1 FE green yellow 1 2 N blue 1 3 L black 2 Connection line PVC AWG20 4 pole connector housing TE 350779 5 3x plug pin TE 926887 1 2 1 not used 2 2 GND blue 2 3 PWM yellow 2 4 Fan go...

Page 5: ...rated into a product 3 4 Technical features Mass 2 467 kg Size 146 mm Motor size 55 Surface of rotor Thick layer passivated Material of electronics housing PP plastic Material of impeller Sheet steel...

Page 6: ...annot be touched by any rotating parts DANGER Electrical load 50 C between mains wire and protective earth connection after switching of the supply when switching multiple devices in parallel Electric...

Page 7: ...e power in this operating state operational readiness is typically 2 W 4 2 3 Locked rotor protection Due to the locked rotor protection the start up current LRA is equal to or less than the nominal cu...

Page 8: ...for voltage range 4 FE green yellow Functional earth conductor 3 FG FB white Fan good fan bad Open collector fan good high electrically isolated Isink max 10 mA 2 PWM yellow Control input PWM impedanc...

Page 9: ...input Do not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the supply voltage When disconnecting be sure to disconnect the earth wire connection last...

Page 10: ...aporation of any water which may have ingressed If cleaning does not eliminate vibration the fan may have to be re balanced In such cases please contact ebm papst The fan is provided with maintenance...

Page 11: ...mostly made of steel copper aluminium and plastic Metallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron...

Reviews: