background image

Operating instructions

D1G146-LV03-06

Translation of the original operating instructions

2. PROPER USE

The device is exclusively designed as a built-in device for conveying
air according to its technical data.
Any other usage above and beyond this does not conform with the
intended purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical
and thermal stresses that can arise from this product. This applies for the
entire service life of the equipment in which this product is installed.

Proper use also includes:

Use of the device in stationary systems only.

Carrying out all maintenance.

Conveying of air at an ambient air pressure of 800 mbar to 1050 mbar.

Using the device in accordance with the permitted ambient
temperature, see chapter 3.6 Transport and storage conditions and
chapter 3.2 Nominal data.

Operating the device with all protective features in place.

Minding the operating instructions.

Improper use

Using the device in the following ways is particularly prohibited and
may cause hazards:

Operating the device with an imbalance, e.g. caused by dirt deposits
or icing.

Resonance mode, operation with heavy vibrations. These also
include vibrations that are transmitted from the customer system to the
fan.

Operation in medical equipment with a life-sustaining or lifesaving
function.

Moving solids content in flow medium.

Painting the device

Connections (e.g. screws) coming loose during operation.

Moving air that contains abrasive particles.

Moving highly corrosive air, e.g. salt spray mist. Exceptions are
devices that are intended for salt spray mist and protected accordingly.

Moving air that contains dust pollution, e.g. suctioning off saw dust.

Operating the device close to flammable materials or components.

Operating the device in an explosive atmosphere.

Using the device as a safety component or for taking on safety-
related functions.

Operation with completely or partially disassembled or modified
protective features.

In addition, all application options that are not listed under proper use.

Item no. 54195-5-9970 · ENG · Revision 225511 · Release 2022-01-11 · Page 3 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for D1G146-LV03-06

Page 1: ...ly authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety haza...

Page 2: ...cal or electromagnetic interferences after integrating the device in installations on the customer s side Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device B...

Page 3: ...and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from...

Page 4: ...pin TE 926887 1 1 1 FE green yellow 1 2 N blue 1 3 L black 2 Connection line PVC AWG20 4 pole connector housing TE 350779 5 3x plug pin TE 926887 1 2 1 not used 2 2 GND blue 2 3 PWM yellow 2 4 Fan go...

Page 5: ...rated into a product 3 4 Technical features Mass 2 467 kg Size 146 mm Motor size 55 Surface of rotor Thick layer passivated Material of electronics housing PP plastic Material of impeller Sheet steel...

Page 6: ...annot be touched by any rotating parts DANGER Electrical load 50 C between mains wire and protective earth connection after switching of the supply when switching multiple devices in parallel Electric...

Page 7: ...e power in this operating state operational readiness is typically 2 W 4 2 3 Locked rotor protection Due to the locked rotor protection the start up current LRA is equal to or less than the nominal cu...

Page 8: ...for voltage range 4 FE green yellow Functional earth conductor 3 FG FB white Fan good fan bad Open collector fan good high electrically isolated Isink max 10 mA 2 PWM yellow Control input PWM impedanc...

Page 9: ...input Do not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the supply voltage When disconnecting be sure to disconnect the earth wire connection last...

Page 10: ...aporation of any water which may have ingressed If cleaning does not eliminate vibration the fan may have to be re balanced In such cases please contact ebm papst The fan is provided with maintenance...

Page 11: ...mostly made of steel copper aluminium and plastic Metallic materials are generally considered to be fully recyclable Separate the components for recycling into the following categories Steel and iron...