background image

 

 

page 7 of 8 

 

FAULTS, POSSIBLE CAUSES AND REMEDIES 

 
Replace your product by a new one, do not repair it. 
 

 

DANGER 

Electrical voltage at motor 
 

Ø

 Wait five minutes after the voltage 

(all poles) has been switched off 
before opening the product.

 

 
 

Fault/  
Error 

Possible cause 

Possible remedial 
action 

Motor is not 
rotating 

Mechanical 
blocking 

Switch off, de-energize 
and eliminate 
mechanical blocking. 

Mains voltage fault  Check mains voltage, 

re-connect voltage 
supply. 

Connection faulty 

Rectify connection, see 
pin connection. 

Motor is too hot 

Allow motor to cool / 
identify cause of fault. 

Motor winding 
interrupted 

Exchange product.  

Ambient 
temperature too 
high 

Reduce ambient 
temperature if possible. 

Impeller out of 
true 

Unbalance of 
rotating parts 

Clean product if still 
unbalanced after 
cleaning, exchange 
product. 

 

 

In case of further faults, contact ebm-
papst. 

 

Technical safety inspection 
 
What requires checking? 

How to 
check? 

Frequency 

Protection against accidental 
contact/ protective clothing 

Visual 
inspection 

min. 1/2 
yearly 

Check product for damage 

Visual 
inspection 

min. 1/2 
yearly 

Fixation of product 

Visual 
inspection 

min. 1/2 
yearly 

Fixation of wires 

Visual 
inspection 

min. 1/2 
yearly 

Insulation of wires 

Visual 
inspection 

min. 1/2 
yearly 

Check impeller for 
wear/sediments/ corrosion 

Visual 
inspection 

min. 1/2 
yearly 

 

COMPLIANCE 

 
The product bears the CE mark. 
 
The CE mark is affixed to adequately sized nameplates. 
 
Within the meaning of the EMC Guideline 2014/30/EU this document is 
intended as: 

 

-

  Mounting instructions/operating manual as per Art. 18, Paragraph 

(1)Installation instructions as per Art. 4 

-

  Operating manual as per Art. 9, Paragraph (3) 

-

  Instructions for use/operating manual as per Art. 18, Paragraph (3) 

-

  Maintenance instructions as per Art.4; Art. 18, Paragraph (1) 

Usage restrictions for residential areas as per Art. 18, Paragraph (2) 
Accompanying documents as per Art. 17, Paragraph (1) 
 
Within the meaning of Directive 2014/35/EU - electrical equipment 
designed  for use within certain voltage limits – this document is 
intended  as: 

-

  Instructions for use/operating manual as per Art. 6, Paragraph (7); 

Art. 8 Paragraph (4) 

 
Within the meaning of the Directive 2006/42/EU Machine Guideline, 
this document is intended as 

-

  Mounting instructions as per Art. 13, Paragraph 1b 

 
The product bears the EAC mark. 
 

The information in this document and in the product data sheet 
applies to mounting, installation, operation, use and maintenance.

 

Summary of Contents for ACi 4400 HHU-511

Page 1: ...hen making enquiries about the product ebm papst St Georgen GmbH Co KG Hermann Papst Straße 1 D 78112 St Georgen Phone 49 0 7724 81 0 Fax 49 0 7724 81 1309 info2 de ebmpapst com www ebmpapst com As per 27 09 2016 Version 0 0 Article number 9203509511 Original operating manual INDEX 1 SAFETY REGULATIONS AND INFORMATION 2 2 INTENDED USE 4 3 TECHNICAL DATA 4 4 CONNECTION AND COMMISSIONING 5 5 FAULTS ...

Page 2: ...o the market requirements of the country in question When working at the product observe the following Ø Do not make any changes to the product WARNING Impermissible high load Ø Stop the product immediately after impermissible loading e g impact heat overvoltage Electrical voltage and current DANGER Electrical voltage Regularly check the electrical equipment of the product Ø Eliminate immediately ...

Page 3: ... well protected Ensure that the storage temperature is adhered to see Chapter 3 Technical Data If the product is not operated for a longer period of time we recommend running it for approx 15 minutes annually to move the motor bearings Cleaning NOTE Product damaged during cleaning Ø Do not clean the product using a water jet or pressure washer Do not put any pressure on the rotor Do not use cleani...

Page 4: ...lated protective equipment Operating the product under conditions other than those mentioned in the technical data Furthermore all fields of application not mentioned under intended use An in situ assessment must be conducted of the heating behavior appropriate and inappropriate operation the protection against contact electrical shocks impact of foreign objects or water and the usage at altitudes...

Page 5: ...ations Ø Observe the connection regulations that are valid in your country e g fusing GFCI CAUTION Electrical voltage The product is a built in component and has no switch for disconnecting power Ø Only connect the product to current circuits that can be switched off by a switch all poles disconnected When working on the product secure the system machine in which the product is installed against s...

Page 6: ...ta Only use cables that are designed for the current on the nameplate and the corresponding ambient conditions Ensure that the electrical interface data is adequately protected mechanical Find additional information in drawing or label Wire Color Operation Check connections NOTE ACmaxx and ACi fans are built in products and must not be earthed Connect product Check the product for visible damage a...

Page 7: ... inspection min 1 2 yearly Fixation of wires Visual inspection min 1 2 yearly Insulation of wires Visual inspection min 1 2 yearly Check impeller for wear sediments corrosion Visual inspection min 1 2 yearly 6 COMPLIANCE The product bears the CE mark The CE mark is affixed to adequately sized nameplates Within the meaning of the EMC Guideline 2014 30 EU this document is intended as Mounting instru...

Page 8: ...page 8 of 8 ...

Reviews: