INTENDED USE 

 
The product is designed exclusively as a built-in device for conveying 
air according to the technical data. 
Every use that is not in accordance with the intended purpose, is 
regarded as misuse of the product. 
On-site installations must comply with the mechanical, thermal and 
service life requirements, 

see Chapter 3, Technical Data.

 

 

Intended use includes: 
 

-  Operating the product with all protective equipment 
-  Do not put the product into operation before it has been installed in 

the customer's application 

-  Observation of the operating manual 
 

Use for other than the intended purpose 

 
Using the product for the purposes mentioned below is prohibited and 
can be dangerous: 
 
-  Conveyance of air that contains abrasive particles. 
-  Conveyance of air that has a highly corrosive effect. 
-  Conveyance of air that has a high dust load, e.g. vacuuming 

sawdust. 

-  Conveyance of inflammable gases/particles. 
-  Contact with materials that can damage the product, e.g. acids, 

caustic solutions, solvents. 

-  Exposure to radiation that can damage product components, e.g. 

strong UV rays or thermal radiation. 

-  Operating during external vibration. 
-  Operating the product close to inflammable materials or 

components. 

-  Operating the product in an explosive atmosphere 
-  Use of the prouct as a safety component or for performing safety-

relevant functions. 

-  Operating in medical devices with life-sustaining or life-saving 

function if not validated together with ebm-papst. 

-  Operating in non-stationary systems, e.g. railway vehicles, aircraft 

and spacecraft if not validated together with ebm-papst. 

-  Operating with fully or partially dismantled or manipulated protective 

equipment. 

-  Operating the product under conditions other than those mentioned 

in the technical data. 

-  Furthermore, all fields of application not mentioned under intended 

use. 

 
An in situ assessment must be conducted of the heating behavior 
(appropriate and inappropriate operation), the protection against 
contact, electrical shocks, impact of foreign objects or water and the 
usage at altitudes higher than 2000 meters. 
 
Contact ebm-papst if you have specific queries regarding the product.

TECHNICAL DATA 

 
Drawing, see annex 
 
Technical description 

Airflow direction 

Air outlet over struts 

Rotating direction looking 
at rotor 

Clockwise 

Frequency 

50 Hz / 60 Hz 

Nominal voltage 

100 V - 240 V 

Current consumption 

70 mA 

32 mA 

Power consumption 

4,4 W 

4,4 W 

Speed 

3.300 1/min 

3.300 1/min 

Max. free-air flow 

175,0 m3/h 

 

Mass 

0,275 kg 

Protection class 

built-in fan 

Max. torque when 
mounted across both 
mounting flanges 

Wire outlet corner: 50 Ncm 
Remaining corners: 80 Ncm 

Screw size 

ISO 4762 - M4 degreased, 
without an additional brace and 
without washer 

 
The product is for the use in open and unsheltered areas. Direct 
exposure to water as well as saline ambient conditions are allowed 
provided that this does not prevent the normal operation. 
 
Pollution degree 3 (according DIN EN 60664-1) 
It occurs conductive pollution or dry non-conductive pollution which 
becomes conductive due to condensation. 
 
 
 

Ambient conditions 
 
Permitted ambient temperature 
Transport and storage 

Operation 

-40 °C ... 80 °C 

-40 °C ... 75 °C 

 

Vibration and shock load 

 
The mechanical Vibration and Shock data for the product is available. 
If the operation of the product should take place in a sinusoidal 
vibration containing environment or fixing the product on sinusoidal 
vibrating surface, please contact our technical support. 
 
Do not operate your product in the resonance range. 

Summary of Contents for ACi 4400 HHU-511

Page 1: ...hen making enquiries about the product ebm papst St Georgen GmbH Co KG Hermann Papst Straße 1 D 78112 St Georgen Phone 49 0 7724 81 0 Fax 49 0 7724 81 1309 info2 de ebmpapst com www ebmpapst com As per 27 09 2016 Version 0 0 Article number 9203509511 Original operating manual INDEX 1 SAFETY REGULATIONS AND INFORMATION 2 2 INTENDED USE 4 3 TECHNICAL DATA 4 4 CONNECTION AND COMMISSIONING 5 5 FAULTS ...

Page 2: ...o the market requirements of the country in question When working at the product observe the following Ø Do not make any changes to the product WARNING Impermissible high load Ø Stop the product immediately after impermissible loading e g impact heat overvoltage Electrical voltage and current DANGER Electrical voltage Regularly check the electrical equipment of the product Ø Eliminate immediately ...

Page 3: ... well protected Ensure that the storage temperature is adhered to see Chapter 3 Technical Data If the product is not operated for a longer period of time we recommend running it for approx 15 minutes annually to move the motor bearings Cleaning NOTE Product damaged during cleaning Ø Do not clean the product using a water jet or pressure washer Do not put any pressure on the rotor Do not use cleani...

Page 4: ...lated protective equipment Operating the product under conditions other than those mentioned in the technical data Furthermore all fields of application not mentioned under intended use An in situ assessment must be conducted of the heating behavior appropriate and inappropriate operation the protection against contact electrical shocks impact of foreign objects or water and the usage at altitudes...

Page 5: ...ations Ø Observe the connection regulations that are valid in your country e g fusing GFCI CAUTION Electrical voltage The product is a built in component and has no switch for disconnecting power Ø Only connect the product to current circuits that can be switched off by a switch all poles disconnected When working on the product secure the system machine in which the product is installed against s...

Page 6: ...ta Only use cables that are designed for the current on the nameplate and the corresponding ambient conditions Ensure that the electrical interface data is adequately protected mechanical Find additional information in drawing or label Wire Color Operation Check connections NOTE ACmaxx and ACi fans are built in products and must not be earthed Connect product Check the product for visible damage a...

Page 7: ... inspection min 1 2 yearly Fixation of wires Visual inspection min 1 2 yearly Insulation of wires Visual inspection min 1 2 yearly Check impeller for wear sediments corrosion Visual inspection min 1 2 yearly 6 COMPLIANCE The product bears the CE mark The CE mark is affixed to adequately sized nameplates Within the meaning of the EMC Guideline 2014 30 EU this document is intended as Mounting instru...

Page 8: ...page 8 of 8 ...

Reviews: