Page 1: ...to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re...

Page 2: ...ured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill DANGER Flying parts Missing safety devices may cause balancing wei...

Page 3: ...ions Improper use Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Resonance mode ope...

Page 4: ...n of air flow V 2 Depth of screw 12 16 mm 3 Connection line PVC AWG18 6x crimped core end sleeves 4 Connection line PVC AWG22 3x crimped core end sleeves Item no 50371 5 9970 ENG Revision 205336 Relea...

Page 5: ...ned using a motor impeller combination in a standardised measurement configuration 3 4 Technical features Mass 12 3 kg Size 910 mm Motor size 112 Surface of rotor Coated in black Material of electroni...

Page 6: ...ater than or equal to 120 times the rated output of the arrangement 4 CONNECTION AND START UP 4 1 Connecting the mechanical system CAUTION Cutting and crushing hazard when removing the fan from the pa...

Page 7: ...y way of the extra protective earth terminal provided on the device The protective earth terminal is located on the housing and provided with a protective earth symbol and a hole 4 2 2 Power supply co...

Page 8: ...perating instructions Control function Positive heating Item no 50371 5 9970 ENG Revision 205336 Release 2020 07 16 Page 8 13 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 79...

Page 9: ...10 mA AC1 1 7 NC white 2 Floating status message contact break for failure 2 8 0 10 V yellow Control input set value 0 10 VDC impedance 100 kOhm SELV 2 11 10 V red Voltage output 10 VDC 3 max 10 mA s...

Page 10: ...ply voltage When disconnecting be sure to disconnect the earth wire connection last 5 INTEGRATED PROTECTIVE FUNCTIONS The integrated protective functions cause the motor to switch off automatically in...

Page 11: ...error message by applying a control signal of 0 5 V to DIN1 or by short circuiting Din1 to GND Unacceptable operating point e g counterpressure is too high Correct the operating point Let the device c...

Page 12: ...urce preservation are top priority corporate goals ebm papst operates an environmental management system which is certified in accordance with ISO 14001 and rigorously implemented around the world on...

Page 13: ...ploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 50371 5 9970 ENG Revision 205336 Release 2020 07 16 Page 13 13 ebm papst Mulfing...