ebm-papst 4656 EZU Operating Manual Download Page 3

page 3 of 5 

 

-  Operating in non-stationary systems, e.g. railway vehicles, aircraft 

and spacecraft if not validated together with ebm-papst. 

-  Operating with fully or partially dismantled or manipulated protective 

equipment. 

-  Operating the product under conditions other than those mentioned 

in the technical data. 

-  Furthermore, all fields of application not mentioned under intended 

use. 

 
An in situ assessment must be conducted of the heating behavior 
(appropriate and inappropriate operation), the protection against 
contact, electrical shocks, impact of foreign objects or water and the 
usage at altitudes higher than 2000 meters. 
 
Contact ebm-papst if you have specific queries regarding the product. 

TECHNICAL DATA

 

 
Drawing, see annex 
 
Technical description 
Airflow direction 

Air outlet over flange 

Rotational direction 
looking at rotor 

clockwise 

Frequency 

50 Hz 

60 Hz 

Nominal voltage 

230,0 V 

230,0 V 

Current consumption 

115 mA 

105 mA 

Power consumption 

19,0 W 

18,0 W 

Speed 

2.600 1/min 

2.950 1/min 

Max. free-air flow 

124,0 m3/h 

142,0 m3/h 

IP-protection type 

IP 65 (for  fan only, not for 
connector if applicable) **) 

Weight 

0,380 kg 

Protection class 

 
The product is for the use in partial sheltered rooms or open, roofed 
areas. Direct exposure to water is allowed provided that this does not 
prevent the normal operation. Saline ambient conditions must be 
avoided. 
 
Pollution degree 3 (according DIN EN 60664-1) 
It occurs conductive pollution or dry non-conductive pollution which 
becomes conductive due to condensation. 
 
 
**) The specification of the IP protection refers to the conditions 
mentioned in certification of the fan. The above mentioned short 
description of the protection scope is not final. For detailed information 
of the respective protection scope and definitions, see certification as 
well as DIN EN 60529 (protection by housings) and ISO 20653 (for 
vehicles) with the letter K. 
 
Short description of the IP-protection type:  
Solid particle Protection: Dust tight. 
Protection against deliberate contact: Protected against contact to 
hazardous parts with a wire. 
Protection against water: Protected against water jets. 
 
 
Ambient conditions 
 
Permitted ambient temperature 
Transport and storage 

Operation 
50 Hz 

60 Hz 

-40 °C ... 80 °C 

-40 °C ... 65 °C 

-40 °C ... 70 °C 

 

Vibration and shock load 
 
At stationary operation: 
 

sinus vibration 

1,0 g; 5 - 500 Hz; 3 x 1 sweep 
(Resonance search run) 

Noise 

0,5 m2/s3, 10 - 50 Hz; +12 
dB/oct f. 5 - 10 Hz; -12 dB/oct f. 
50 - 100 Hz; 3 x 30 min 

Repetitive shock 

Half sine; 5 g, 11 ms; 6 x 100 
shocks 

 
Transport and storage:  
 

Noise 

2,0 m2/s3, 5 - 20 Hz;  -3 dB/oct f. 
20 - 500 Hz; 3 x 30 min 

Thrusts 

Half sine; 18 g, 6 ms; 6 x 100 
shocks 

 
Do not operate your product in the resonance range.  

CONNECTION AND COMMISSIONING

 

 
Connect mechanical parts 
 

 

CAUTION 
Risk of cutting/squashing when 
removing the product from the 
packaging and during mounting. 
 
Grasp the housing and lift the product 
carefully out of the packaging. Avoid 
impact. 

 

Wear safety boots and cut-resistant 
gloves. 

 

 
 
 
 

Connect electrical parts 
 
Connect to the mains after installation. 
 

 

DANGER 
Do not touch. Risk of fatal injury 
from electrical current. 
 

 

Ensure that the electrical lines are 
de-energized. 

 

Secure the operating voltage against 
switching on again. 

 

Never work on parts that are 
energized. Only allow skilled 
electricians to work on the product. 

 

 

DANGER 
Compliance with the electrical 
installation regulations 
 

 

Observe the connection regulations 
that are valid in your country. (e.g. 
fusing, GFCI) 

 

 

CAUTION 
Electrical voltage 
The product is a built-in 
component and has no switch for 
disconnecting power.
 
 

 

Only connect the product to 
current circuits that can be 
switched off by a switch (all poles 
disconnected). When working on 
the product, secure the 
system/machine in which the 
product is installed against 
switching on again. 

 
 

Summary of Contents for 4656 EZU

Page 1: ...k ratings are used in this operating manual to denote potential risk situations and important safety instructions DANGER This is a potentially dangerous situation and warns of an impending health risk or risk of fatal injury if this warning is not observed Observe this warning WARNING The dangerous situation can occur and can result in major or fatal injuries if the warning is not observed Work wi...

Page 2: ...ansport Storage Store the product in a dry and clean environment that is well protected Ensure that the storage temperature is adhered to see Chapter 3 Technical Data If the product is not operated for a longer period of time we recommend running it for approx 15 minutes annually to move the motor bearings Cleaning NOTE Product damaged during cleaning Do not clean the product using a water jet or ...

Page 3: ...fication as well as DIN EN 60529 protection by housings and ISO 20653 for vehicles with the letter K Short description of the IP protection type Solid particle Protection Dust tight Protection against deliberate contact Protected against contact to hazardous parts with a wire Protection against water Protected against water jets Ambient conditions Permitted ambient temperature Transport and storag...

Page 4: ...ly Connection faulty Rectify connection see pin connection Motor is too hot Allow motor to cool identify cause of fault Motor winding interrupted Exchange product Motor is not rotating Ambient temperature too high Reduce ambient temperature if possible Impeller out of true Unbalance of rotating parts Clean product if still unbalanced after cleaning exchange product In case of further faults contac...

Page 5: ...page 5 of 5 ...

Reviews: