Basic Installation Concept & Accessories
Spec
Model
Voltage Input
Dimension
300-S
12VDC / 24VDC *
(L)170 x (W)35 x (T)22 (mm)
Current Draw
300mA / 150mA
12VDC / 24VDC
Power Supply
Self-tapping Screw x 5
Mounting Plate
Cable Wire
Armature Plate
Electromagnet
Guide Pin x2
Sexnut Bolt
Rubber
Washer
Metal
Washer
Armature
Screw
Fixing Screw
x2
12VDC / 24VDC
Power Supply
Wiring Instruction
1-2
Allen Wrench
T Handle Allen Key
(Not include in package)
* Note:
12VDC / 24VDC is pre-set
upon manufacture; once it
set, it cannot be changed.
Electromagnetic Lock
Installation Instruction Guide
(Intend for use in indoor dry location)
Notice:
Model are Recognized to:
UL 294
: Standard for Access Control System Units, 6th Ed.
ULC S533-15: Standard for Egress Door Securing &
Releasing Devices, 4th Ed.
Out Swing
EM Lock
Door
Frame
General Installation
Door Frame
Out-Swing
Glass
Door
EM Lock
Door
U1 Bracket For
Glass Door
Door
Out-Swing
EM Lock
Door
Frame
ZL Bracket For
In-Swing Door
LS Bracket For
Out-Swing Door
Door
Frame
Door
EM Lock
Self-tapping Screw
In-Swing
AH Bracket Fire Door Application
Out Swing
Door
Frame
Door
EM Lock
Armature Plate
Armature
Housing
DSU Bracket For
Glass Frame & Glass Door
EM Lock
In-Swing
Glass
Door
Glass
Frame
Holding Force
Up to 300 lbs (Factory Tested)**
** Value not verified by UL.
General Installation Steps & Maintainance
1.
2.
Close the door & position the template at the lock jamb side of the frame with a gap 10mm.
3. Mark & drill holes according to template indications.
4. Install the Armature Plate to the door.
5. Loosely tighten screw through the adjustable slot on mounting plate to the door frame as indicated on
installation template.
6. Make sure the mounting plate & armature align properly, then screw in the balance mounting screws.
7.
Use allen wrench to unscrew anti tamper nut and install the lock by tighten the fixing screws on the
mounting plate. Pull cable wire through frame to lock housing.
8. Screw in the anti-tamper nuts to prevent unauthorized access and make sure to fully tighten the fixing
screw with proper tool "T" Handle Allen Key.
9. Connect the power wires accordance with NFPA 101 & all wiring to be completed inside protect area.
10. Typical wiring method which shall be in accordance with CSA C22.1, Canadian Electrical Code, Part I,
Safety Standard for Electrical Installations, Section 32.
11. It is recommended that to apply a light coat of silicon lubricant to the mating surface on a monthly
basis to prevent rust.
Trouble Shooting
1.
Sensor not functioning
- Improper attachment of electromagnet and
armature plate
- Modification of the PCB
2. Door not locked
- Incorrect wiring or no power from power supply
3. Reduced holding force
- Poor contact of electromagnet and armature.
- Be sure armature is loose enough that it can fully
contact electromagnet along the entire length.
- Mating surface is dusty or damaged.
- Improper input voltage or wire size.
Performance Level
- Destructive Attack: Level I
- Line Security: Level I
- Standby Power: Level I
- Endurance 250,000 Cycles: Level IV
(Relay Source #2 & #3)
Remark: All drawing shown are for illustration purpose only.
Actual product may vary due to product enhancement.
EISB-EMS-IG Ver.A Publish:06.3.2020