background image

 

Specifications    Environmental 

 

Operating Temperature 

0

  to +40

 

Pollution Degree    2 

Type of protection IP 40 

Mechanical Specifications   

Size (H x W x D): 130mm

 

x

 

69mm x 32mm. 

Weight: 130g 

Safety Specifications 

Electrical Safety 

IEC 61010/EN61010, 

IEC 61557-7/EN 61557-7 

Maximum Operating Voltage (Ume)    690 V 

Protection Levels 

CAT lll, 600V to ground 

Electrical Specifications 

Power Supply 

From unit under test   

Determine Rotary Field Direction 

Summary of Contents for 95608

Page 1: ...1 Phase rotation indicator 95608 PHASE ROTATION INDICATOR ...

Page 2: ...c shock Earth Risk of Danger Important information See manual AC or DC Hazardous Voltage Conforms to EU directives Equipment protected by double or reinforced Insulation OVERVOLTAGE Installation CATEGORY III Pollution Degree 2 per IEC 1010 1 refers to the level of Impulse Wishstand Voltage protection provided Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations e g electricity...

Page 3: ...ack L1 L2 L3 Indicators Clockwise Rotation LCD Indicator Counter Clockwise Rotation LCD Indicator Brief Instructions on instrument rear Figure 1 The phase Rotation Indicator Determine the Rotary Field Direction To determine the rotary field direction 1 Connect the test probes to the end of the test leads 2 Connect the test probes to the three mains phases ...

Page 4: ... field direction present 5 The rotary indicator lights even if the neutral conductor N is connected instead of the Test lead input jacks Unpacking the phase Rotation indicator The phase Rotation indicator ships with the following items 3 pieces self retaining test probes Alligator clip Users Manual If an item is damaged or missing contact the place of purchase immediately ...

Page 5: ... First Safety Information To avoid possible electric shock or fire do the following Read the following safety information carefully before using or servicing the instrument Adhere to local and national safety codes Individual protective equipment must be used to prevent shock and injury Use of instrument in a manner not specified by the manufacturer may impair safety features protection provided b...

Page 6: ...way from probe contacts Keep fingers behind the finger guards on the probes Measurements can be adversely affected by impedances of additional operating circuits connected in parallel or by transient currents Verify operation prior to measuring hazardous voltages voltages above 30V ac rms 42V ac peak and 60V dc Do not use the phase Rotation indicator with any of the parts removed Do not use the ph...

Page 7: ...al Specifications Size H x W x D 130mm x 69mm x 32mm Weight 130g Safety Specifications Electrical Safety IEC 61010 EN61010 IEC 61557 7 EN 61557 7 Maximum Operating Voltage Ume 690 V Protection Levels CAT lll 600V to ground Electrical Specifications Power Supply From unit under test Determine Rotary Field Direction ...

Page 8: ...8 Nominal Voltage 40 to 690 VAC Frequency Range fn 15 to 400HZ Current pickup 1 mA Nominal Test current in per phase 1 mA ...

Reviews: