- 3 -
Install the pump in the locked pump room or equipment room.
When it is placed outside, please arrange the fence and cover to
avoid easy touch by the third person. If the rotating or
high-temperature part is touched, unimaginable injury may
happen.
Please arrange specific short circuit breaker for this pump. It is
suggested to install the wiring breaker with electric leakage alarm
output. Otherwise, it may cause electric shock and fire.
Close the suction and discharge valves, drain the casing drain,
and ensure that the pump pressure is not abnormal or negative
when disassembly and inspections. The pump may undergo
abnormal rotation while the work is incomplete, resulting in
damage to the casing.
Do NOT touch the rotating parts such as the spindle, shaft
couplings, V-pulleys, etc. while the pump is running. Since these
parts rotate at high speed, doing so could result causing injury.
Disassembly and repair of the pump should only be performed by
specialist maintenance technicians. Otherwise, error by personnel
could result in electric shock, fire or operating abnormally and
causing injury.
Do not pour water on the motor. Otherwise, it may cause electric
shock, electric leakage, fire and others.
Please use the anchor bolts to firmly fix the pump. In case of pump
toppling, there will be injury danger. In addition, it may lead to pipe
damage danger due to pump vibration.
Install the coupling guard after the couplings are aligned. In
addition, during pump operation; don’t be close to the rotating
parts to prevent damage.
Please confirm that there are no loose wire connections on the
motor, the primary side and secondary side of control panel, the
electrical equipment in the control panel; and remove the dust. If
bad connection or dust adsorbed on the terminal part due to lose
wire connection, it may lead to heating and danger of fire accident.
Do NOT install the pump and motor near dangerous and
flammable articles. Otherwise, it may cause fire due to ignition.
Warning
Do NOT touch the charge part under turning power switch on.
Otherwise, there is the danger of electric shock.
Do NOT burn plastic components. In case of burning, it may
generate harmful gases.
Do NOT install the pump outdoors or in locations exposed to water
unless the motor is designed for outdoor use. Otherwise, it may
cause electric leakage, electric shock and fire due to deteriorated
insulation or other reasons.
Do NOT install non-genuine parts or modify the pump. Otherwise,
there is a danger of electric shock and fire, as well as malfunction
and breakage of the pump, which may result in bodily injury. Also,
the normal functioning of the pump may be impaired.
NEVER use or work with the pump while it is lifted or suspended
off the floor or ground. Otherwise, it may fall and cause bodily
injury.