- 1 -
Safety Information and Introduction
This pump should only be serviced by a qualified person or a factory trained person.
This instruction manual includes necessary items for installation, operation and maintenance.
Read this manual carefully to ensure correct installation, operation and maintenance.
Be sure to keep this instruction manual on hand for future reference.
Design of this EBARA pump is based on superior engineering and long experience. To prevent trouble and provide
satisfactory operation and long life, it is important to understand the EBARA pump thoroughly by careful study of this manual.
If any questions arise regarding this manual, please direct them to EBARA INDONESIA.
Specification
Be careful not to exceed the given specifications in the use of your products.
Check the following points upon receipt of your pump:
(1) The pump exactly what you ordered? Check the
nameplate. It is especially important that you check
whether the pump is to be used with 50 Hz.
(2) Has any damage occurred during shipment? Are any
bolts or nuts loose?
(3) Have all necessary accessories been supplied? (For
a list of standard accessories see Construction.)
We recommend that you keep a spare pump on hand in
case of emergencies. Keep this instruction manual in a
safe place for future reference.
Standard Optional
Description
2 poles model
4 poles model
2 poles model
4 poles model
Name
Clean water
Liquid
Temperature
0 to 100
o
C (32 to 212
o
F)
10 bar (10.2 kgf/cm
2
) for standard flange JIS 10K RF
16 bar (16.3 kgf/cm
2
)
Max. Working Pressure
16 bar (16.3 kgf/cm
2
) for standard flange JIS 16K RF
Synchronous Speed
3000 min
-1
1500 min
-1
Installation
Indoors
Outdoors
Impeller
Enclosed
Shaft seal
Mechanical seal
Gland Packing
Sealing
Self flushing
External flushing
Construction
Bearing
Sealed ball bearing
Oil bath (some models only)
Suction <
φ
150 mm, except 100x65 FSKA
: JIS 10K RF
16 bar : JIS 16K RF; DIN PN-16
100x65 FSKA
: JIS 16K RF
DIN PN-16
Suction =
φ
150 mm, except below models
: JIS 10K RF
16 bar : JIS 16K RF; DIN PN-16
150x100 FSKA; 150x100 FSNA
: JIS 16K RF
DIN PN-16
Suction =
φ
200 mm, except below models
: JIS 10K RF
16 bar : JIS 16K RF; DIN PN-16
200x150 FSLA; 200x150 FSNA
: JIS 16K RF
DIN PN-16
Flange
Suction & Discharge
Suction =
φ
250
: JIS 16K RF
DIN PN-16
Casing
Cast Iron
Ductile Cast Iron (FCD)
Impeller
Bronze Casting (CAC406/BC6)
Cast iron; Ductile Cast Iron (FCD)
Shaft
403 Stainless steel
304; 316 Stainless steel
Gland Packing : Teflon (PTFE) impregnated
Material
Seal
Mechanical Seal: Ceramic/Carbon/NBR
Mechanical Seal : SiC/SiC
Bare shaft
Priming funnel ; valve; Companion Flange
Accessories
With motor
Common base, Coupling, Coupling guard
Priming funnel ; valve; Companion Flange
WARNING
Before handling this pump, always disconnect the power first. No open flame or use sparkable
electrical devices or flames in a septic (gaseous) or possible septic sump.
Do not work under heavy Suspended object unless there is a positive support under it to stop its fall in
event of sling or, hoist failure. Disregard of this warning could result in personal injury.
CAUTION
CAUTION
(Kg/cm
2
=98,6 kPa)
Note :
Refer to the Standard Specification if you have purchased a standard model. We also offer pumps with optional features
according to customer demand.
Be careful not to exceed the given specification on the use of your pump.