EBARA DMLU Instruction And Operation Manual Download Page 7

DMLU

Troubleshooting

Project:

Model:

Chk’d:

Date:

Trouble

Motor won’t turn.
Starts, but immediately
stops.

Operates, but stops after
a while.Thermal protector
is activated.

Does not pump.
Inadequate volume.

Overcurrent

Pump vibrates;
excessive noise during
operation.

Cause

(1) Foreign matter hinders level control float from functioning
properly.
(2) Power failure.
(3) Large voltage unbalance.
(4) Significant drop in voltage
(5) There is an open phase 
(6) Faulty circuit connection
(7) Blown fuse 
(8) Faulty starter
(9) Defective float
(10) Malfunctioning circuit breaker
(11) Foreign matter clogging pump
(12)  Motor is shorted out
(13) Motor bearings are frozen

(1) Prolonged dry operation has activated motor protector

and caused pump to stop

(2) High liquid temperature has activated motor protector

and caused pump to stop

(1) Reverse rotation
(2) Valve is closed or partially clogged.
(3) Significant drop in voltage
(4) Discharge head is too high
(5) Large piping loss
(6) Low water level during operation causes vortexing (air
suction)
(7) Leak in discharge piping
(8) Clog in discharge piping
(9) Foreign matter clogging pump
(10) Worn impeller

(1) Large discrepancy between power source and voltage 
(2) Significant voltage drop
(3) There is an open phase

(4) Reverse rotation
(5) Low head; pumping too much liquid
(6) Foreign matter clogging pump
(7) Motor bearing is worn or damaged

(1) Reverse rotation
(2) Pump clogged with foreign matter
(3) Piping vibrates

Remedy

(1) Remove foreign matter

(2 - 3) Contact electric power company for remedy

(4) Check power supply
(5) Check power supply; Inspect starter and connections
(6) Correct wiring
(7) Replace with correct size fuse
(8) Replace with correct starter
(9) Repair or replace float
(10) Repair location of circuit
(11) Remove clog from pump
(12) Repair or replace
(13) Repair or replace

(1) Raise the off float level

(2) Lower liquid temperature

(1) Correct rotation
(2) Open valve
(3) Check power supply
(4) Recalculate and adjust
(5) Recalculate and adjust
(6) Raise water level or lower pump

(7) Inspect, repair
(8) Remove foreign matter
(9) Remove foreign matter
(10) Replace impeller

(1) Contact power company for remedy
(2) Contact power company for remedy
(3) Check power supply

Inspect starter & electrical connections

(4) Check rotation
(5) Adjust discharge valve to desired flow
(6) Remove clog from the pump
(7) Repair or replace

(1) Correct rotation
(2) Remove clog from pump
(3) Install support for discharge piping

CALL 1-800-577-8111 FOR SALES AND SUPPORT

CALL 1-800-577-8111 FOR SALES AND SUPPORT

Summary of Contents for DMLU

Page 1: ...Instruction and Operation Manual Model DMLU CALL 1 800 577 8111 FOR SALES AND SUPPORT CALL 1 800 577 8111 FOR SALES AND SUPPORT...

Page 2: ...and can cause electrical shorts that can possibly lead to fires 3 A qualified electrician should perform all wiring and all national and local electrical codes must be observed 4 Make sure that all e...

Page 3: ...tions that you ordered Fig 1 Pump Nameplate Specifications Item Liquid handled Type Temperature Solids Capacity Discharge size in Solid size in Materials Impeller Phase Hz Motor Voltage Starting Metho...

Page 4: ...submerged as it will result in backflow when the pump stops g Set control operating levels i e floats so that pump is not running for more than ten minutes with water level at minimum operating level...

Page 5: ...ion 2 Check to make sure there is an adequate amount of water in the wet well Continuous operation of the pump in a dry condition will cause the motor protector to be activated 3 Check the direction o...

Page 6: ...ir may be required 3 Recommended annual inspections a Check the oil in the seal chamber If the oil has turned white it is an indication that water has mixed with the oil and the mechanical seal needs...

Page 7: ...tween power source and voltage 2 Significant voltage drop 3 There is an open phase 4 Reverse rotation 5 Low head pumping too much liquid 6 Foreign matter clogging pump 7 Motor bearing is worn or damag...

Page 8: ...mber d Remove the mechanical seal carefully to keep from damaging the seal faces 2 Reassembly a Perform the above instructions in reverse order replacing the o ring seal washer and gasket Note 1 After...

Page 9: ...TAINLESS STEEL BRONZE CAST IRON RUBBER NBR BRASS STAINLESS STEEL NO FOR 1 UNIT 1 1 1 1 1 1 1 SET 1 SET 1 1 1 1 PART NO 811 814 816 817 830 849 1 849 2 876 904 907 PART NAME SUBMERSIBLE CABLE MOTOR FRA...

Page 10: ...RONZE CAST IRON RUBBER NBR BRASS STAINLESS STEEL NO FOR 1 UNIT 1 1 1 1 1 1 1 1 SET 1 1 1 1 PART NO 811 1 811 2 814 816 817 830 849 1 849 2 856 904 907 PART NAME SUBMERSIBLE CABLE POWER SUBMERSIBLE CAB...

Page 11: ...RONZE CAST IRON RUBBER NBR BRASS STAINLESS STEEL NO FOR 1 UNIT 1 1 1 1 1 1 1 1 SET 1 1 1 1 PART NO 811 1 811 2 814 816 817 830 849 1 849 2 856 904 907 PART NAME SUBMERSIBLE CABLE POWER SUBMERSIBLE CAB...

Page 12: ...pair or replacement of any defective Pump Customer shall be responsible for labor cost of removal and installation at Customer s premises transportation and insurance costs to EIC RH and any other inc...

Reviews: