![EBARA A70W Instruction Manual Download Page 30](http://html1.mh-extra.com/html/ebara/a70w/a70w_instruction-manual_4076001030.webp)
(16)
4 Installation
Observe the following precautions and instructions when installing the pump.
4.1 Location
This pump is suitable for indoor installation. To install the pump, select a place not exposed
to dust or humidity and not subject to dew condensation. Also, allow sufficient space to
ensure easy pump installation and disassembly for maintenance. If the pump has an
interface box, locate it within 3m of the pump.
CAUTION
Install pump in a location where ambient temperature does not exceed
30
℃
. Exercise extra caution when operating the pump in an enclosed
room.
CAUTION
Leave a gap of at least 50mm between the pump cover and adjacent
equipment for ventilation.
Four integral mobile support units, each consisting of a caster and a height-adjustment foot,
support the pump base. To move the pump, raise the four adjustment feet by turning the
holding nuts in the counterclockwise direction.
Figure 4.1 Caster
WARNING
Be careful not to overturn the pump when pushing or pulling it
sideways. The pump is narrow in comparison to its height.
CAUTION
The neck portion of the casters will vibrate when the caster is moving.
Keep fingers and feet away.
CAUTION
Do not step on the pump or place objects upon it.
Turn the holding nuts in the clockwise direction to lower the height-adjustment feet and
secure the pump.
Adjust the height of the feet evenly to level the pump base.
The difference in height between the two sides of the pump base shall not exceed
1mm. The adjustment allowance is approximately 15 mm.
[NOTE]
An unleveled pump may generate an OIL LEVEL LOW ALARM.
[NOTE]
Failure to use adjustment feet will increase floor vibrations.
EBARA
Corporation
Summary of Contents for A70W
Page 9: ...vii EBARA Corporation...
Page 10: ...viii EBARA Corporation...
Page 11: ...ix EBARA Corporation...
Page 14: ...xii Blank page EBARA Corporation...
Page 21: ...7 EBARA Corporation Outline Drawing A70W...
Page 22: ...8 Outline Drawing A30W EBARA Corporation...
Page 23: ...9 EBARA Corporation Outline Drawing A25S...
Page 24: ...10 EBARA Corporation Outline Drawing A10S...
Page 25: ...11 EBARA Corporation Outline Drawing A07V...
Page 60: ...46 Blank Page EBARA Corporation...
Page 63: ...III Label Country US Label Emergency Number 716 293 3330 EBARA Corporation...