Safety Cautions

 

 

 

Warning

 

Carry  out  the  construction  correctly  in  accordance  with 
electrical  equipment  technical  standards,  interior  wiring 
regulations, Building Standards and applicable regulations.

 

 

Work  safely  by  confirming  weight  and  form  from  the  outline 
drawing, catalog, etc. prior to hoisting. 

 

Never use the product or install parts while it is hoisted. This is 
very dangerous. The equipment may fall. 

 

Fasten  the  pump  securely  with  anchor  bolts  to  prevent  it 
overturning. 

 

Perform wiring work correctly as specified by electrical facility 
technical  standards  and  extension  codes.  Incorrect  wiring 
could result in electric shock and fires. 

 

Install  and  ground  an  earth  cable.  Electric  shock  could occur 
during accidents or electric leakage. 

 

To  prevent  electric  shocks,  install  a  dedicated  earth  leakage 
breaker. 

 

Before  wiring  the  motor,  measure  the  insulation  resistance 
using  an  insulation  tester  (DC  500  V  megger).  Confirm  that 
there is a value of 5M

Ω

  or more between the motor lead wire 

and the ground. 

 

Do  not  operate  the  pump  for  more  than  1  minute  with  the 
discharge valve left closed. 
The pressure within the pump will rise, and the casing or plugs 
may be damaged. 

 

Do  not  touch  the  rotating  parts  such  as  the  spindle,  shaft 
couplings,  V-pulleys,  etc.  while  the  pump  is  running.  Since 
these  parts  rotate  at  high  speed,  doing  so  could  result  in 
injury. 

 

Disassembly and repair of the pump should only be performed 
by  specialist  maintenance  technicians.    Otherwise,

 

error  by 

personnel  could  result  in  electric  shock,  and  the  pump 
catching fire or operating abnormally and causing injury. 

 

Always  turn  the  power  switch  OFF  before  inspecting  or 
repairing  the  pump.    Not  doing  so  could  result  in  the  pump 
starting up suddenly in auto operation, exposing personnel to 
danger. 

 

If there is a power failure, turn the power switch off. 
Otherwise,  the  pump  may  start-up  suddenly  when  the  power 
supply is resumed, exposing personnel to danger. 

 

For  disassembly  and  inspections,  close  the  suction  and 
discharge  valves,  drain  the casing  drain,  and  ensure  that  the 
pump  pressure  is  not  abnormal  or  negative.  The  pump  may 
undergo  abnormal  rotation  while  the  work  is  incomplete, 
resulting in damage to the casing. 

 

In  facilities  with  living  matter  (fish  farms,  fish  preserves, 
aquariums,  etc.),  always  prepare  a  spare  pump,  as  oxygen 
deprivation may result due to pump failures.   

 

Summary of Contents for 25EVMS106.75

Page 1: ...opies of this manual to the customer s pump operation maintenance and inspection personnel Keep this manual in a safe place where it can be consulted at any time To installation personnel Be sure to i...

Page 2: ...tions that they give without fail Warning grade Meaning Warning Potentially hazardous situation Failure to follow the instructions could result in death or serious injury Caution Failure to follow the...

Page 3: ...the discharge valve left closed The pressure within the pump will rise and the casing or plugs may be damaged Do not touch the rotating parts such as the spindle shaft couplings V pulleys etc while t...

Page 4: ...ected Running the motor with only two terminals connected could a phase interruption burning out the motor Pump failures are possible when operated with less flow rate than appropriate for the pump si...

Page 5: ...and that bolts and nuts have not become loose Nameplate The pump s basic specifications are inscribed on the nameplate Check the nameplate to ensure that the equipment is as ordered Caution Do not op...

Page 6: ...orm of optional specifications on request of the customer Do not use the equipment beyond the scope of the specifications The equipment cannot be used for food related fluid transport In facilities wi...

Page 7: ...S329A Wear ling Model EVMS PPS SUS304 Model EVMSL PPS SUS316 Motor 4 5 Phase pole 3 phase 2 pole Voltage 50Hz 200V 60Hz 200 220 230V Type Totally enclosed fan cooling type outdoor Efficiency IE3 Premi...

Page 8: ...l seal SiC SiC type Liquid temperature 0 90 Purified water type Liquid temperature 25 5 Different motor Different voltage Special different voltage Terminal box position change every 90 Tropical treat...

Page 9: ...2EVMS L 35 55 1 09 11 1 32EVMS L 45 75 0 99 10 1 32EVMS L 551 1 0 88 9 32EVMS L 751 5 0 69 7 32EVMS L 1152 2 0 30 3 1 32EVMS L 1553 0 0 99 10 1 32EVMS L 2054 0 0 51 5 2 32EVMS L 2755 5 0 08 0 8 40 40E...

Page 10: ...75 26 75 361 1 461 5 662 2 863 0 1164 0 1565 5 1967 5 1 09 11 1 32EVMS L 361 1 0 95 9 7 32EVMS L 461 5 0 81 8 3 32EVMS L 662 2 0 53 5 4 32EVMS L 863 0 0 25 2 5 32EVMS L 1164 0 0 92 9 4 32EVMS L 1565...

Page 11: ...hould be 40 or below 5 Select a place that is convenient for pump maintenance 6 Take measures such as enclosing the pump to keep unqualified personnel away from the equipment 7 Install the pump in a l...

Page 12: ...g gradient towards the pump and do not install a gate valve There should be sufficient seals to ensure that air is not sucked in from suction pipe connectors c As shown in Fig 3 avoid convex parts alo...

Page 13: ...the motor lead wire and the ground Caution With 3 phase motors check that none of the 3 motor terminals is loose or has become separated Phase interrupted operation will result when the equipment is o...

Page 14: ...laying of the pipes Please install a strainer in the suction side so that alien substance chip of laying of the pipes sand patina and the scale etc doesn t get mixed in a pump at this time I have to d...

Page 15: ...se Close ball valve after confirming that water comes out from the air vent plug Close the air vent plug Note We have priming set by sold separately without hose Please order 4 When priming manually r...

Page 16: ...ver operation may result in noise and vibrations Further unnecessary power consumption will result Avoid operation in the state of cavitation occur Over capacity operation may result in cavitation Cav...

Page 17: ...the pump is out of use for prolonged periods such as the wintertime water inside the pump could freeze causing damage to the pump Accordingly in such situations either drain all water from the pump o...

Page 18: ...of the motor once a month If insulation resistance is 5M or more it does not interfere with driving When insulation resistance is 1M or less or 5M or more but suddenly decreasing it can be guessed th...

Page 19: ...nterior bearings Pump size Frequency Hz Mechanical seal Part name Pump size Bearing Sleeve Intermediate casing for bearings 25 50 12 16F 25k EVMS EVMSL 60 12 16F 25k 25 12 16 10 5 21B1 30 6 304 5 21B1...

Page 20: ...Review the plan Suction head is too high for the pump Discharge head is too high for the pump Review the plan High fluid temperature or volatile fluid Review the plan Cavitation Consult with EBARA Wat...

Page 21: ...Construction This figure shows a typical model EVML E pump there may be some differences from this figure depending on its model size EBARA has prepared sectional views with the material names for co...

Page 22: ...1 4 Seal holder 1 111 5 Adjust sleeve 1 115 1 O Ring out casing 2 115 4 O Ring cartridge sleeve 1 115 5 O Ring seal cover 1 120 1 Tie rod 4 120 3 Screw for seal cover 4 120 6 Screw for coupling 4 120...

Page 23: ...mp remove the drain plug 212 1 for the lower casing 6 3 Remove the cross recessed head machine screws a total of 4 on both sides 130 2 holding the coupling guard 245 and remove the coupling guard 4 Lo...

Page 24: ...nts on the surface of the mechanical seal s sliding faces 1 Coat the shaft 31 the inside of the cartridge sleeve and the O rings at the mechanical cover 111 3 outside with propylene glycol etc Also if...

Page 25: ...et screws a total of 3 screws 130 1 9 Secure the motor 800 to the motor bracket with the hexagon bolt 120 13 4 0 kW or less models only Note Rotate the coupling manually and check that the rotation is...

Page 26: ...e Customs duty and tax in destination are not included And we don t take responsibility to compensate any of secondary loss caused by our pump trouble 3 In following cases replacement and repairing co...

Reviews: