background image

Page 9 of 12 

Drawing   : - TPC519 
Issue 

: - 1 

Date 

: - 03/03//20 

RM40-SH 

SPARE PARTS LIST 

N

UMBER

 

D

ESCRIPTION

 

P

ART

N

UMBER

 

Q

UANTITY

 

Timer 

1619519 

Refrigerant Coil Set 

2018743 

Capillary 

3014254 

1.64ft 

Solenoid valve 

3020836 

Filter dryer 

3020937 

Solenoid coil 

3030451 

Fan Motor 

3947012 

Fan Blade 

3947014 

Compressor 

3944954 

10 

Humidistat 

3035158 

11 

Mains Cable 

2141095 

E B A C   R M 4 0 S H   O W N E R ' S   M A N U A L 

Pure n Natural Systems, Inc.  |  purennatural.com  |  1-800-237-9199

Summary of Contents for RM40-SH

Page 1: ...Page 1 of 12 Drawing TPC519 Issue 1 Date 03 03 20 RM40 SH INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL E B A C R M 4 0 S H O W N E R S M A N U A L Pure n Natural Systems Inc purennatural com 1 800 237 9199...

Page 2: ...RM40 SH PACKAGE CONTENTS Item Description Quantity 10187SH US Dehumidifier 1 3014338 PVC tube 12mm I D 3 M 3086101 Jubilee clip 1 TPC519 Manual 1 E B A C R M 4 0 S H O W N E R S M A N U A L Pure n Na...

Page 3: ...ected in the condensate tray which is equipped with a permanent drain The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling ph...

Page 4: ...ts manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL RM40 SH HEIGH...

Page 5: ...rve the evaporator coils to confirm frost formation i If the air temperature is below 70 F an even coating of frost should cover the entire evaporator coils except for the last one or two coils ii If...

Page 6: ...mperatures above 25 C the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low cha...

Page 7: ...be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant c...

Page 8: ...cked filter dryer 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center 4 Contact the Factory Service Center Little or no defrost when required 1 Faulty Ti...

Page 9: ...t Coil Set 2018743 1 3 Capillary 3014254 1 64ft 4 Solenoid valve 3020836 1 5 Filter dryer 3020937 1 6 Solenoid coil 3030451 1 7 Fan Motor 3947012 1 8 Fan Blade 3947014 1 9 Compressor 3944954 1 10 Humi...

Page 10: ...y sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained...

Page 11: ...Page 11 of 12 Drawing TPC519 Issue 1 Date 03 03 20 E B A C R M 4 0 S H O W N E R S M A N U A L Pure n Natural Systems Inc purennatural com 1 800 237 9199...

Page 12: ...ate 03 03 20 Distributed by Pure n Natural Systems Inc PO Box 1137 Streamwood IL 60107 purennatural com 1 800 237 9199 FAX 630 540 9717 E B A C R M 4 0 S H O W N E R S M A N U A L Pure n Natural Syste...

Reviews: