Ebac CD85 Owner'S Manual Download Page 12

Page 12 of 15 

Drawing   : - TPC361 
Issue 

: - 3 

Date 

: - 03/10/12 

LIMITED WARRANTY

Our  products  carry  a  one-year  unconditional  warranty  against  any  defects  in 
workmanship or material.  This warranty will cover all parts and labor required 
to  repair  your  Ebac  product.    This  warranty  is  invalid  if  the  unit  has  been 
abused,  damaged,  whether  intentional  or  accidental,  or  if  any  modifications 
have been made to the unit. 

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS ISSUED IN LIEU OF 
ALL  OTHER  WARRANTIES  (WHETHER  WRITTEN,  ORAL,  OR  IMPLIED) 
INCLUDING  THE  WARRANTY  OF  MERCHANTABILITY  AND  THE 
WARRANTY  OF  FITNESS  FOR  A  PARTICULAR  PURPOSE.    EBAC 
INDUSTRIAL  PRODUCTS,  INC.  DISCLAIMS  ANY  LIABILITY  FOR 
CONSEQUENTIAL  DAMAGES,  LOST  PROFITS,  OR  INCIDENTAL 
DAMAGES  FOR  BREACH  OF  ANY  WRITTEN  OR  IMPLIED  WARRANTY 
WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE. 

For Your Records:  Model:____________________ 

S/N:______________________ 
Date Received:______________ 

SAVE THIS SECTION FOR YOUR RECORDS 

CLIP AND RETURN THIS CARD 

PLEASE NOTE 

WARRANTY REGISTRATION 

To  ensure  that  your 
Ebac  Dehumidifier  is 
accorded 

the 

full 

coverage  provided  by 
this  warranty,  please 
complete  and  mail  this 
card  at  your  earliest 
convenience. 

Thank You

     DATE 

MODEL ___________  S/N ________________  RECEIVED ________________ 

OWNER __________________________________________________________ 

ADDRESS ________________________________________________________ 

CITY __________________________ STATE ________  ZIP _______________ 

COMMENTS ______________________________________________________ 

_________________________________________________________________ 

Ebac Industrial Products. 

700 Thimble Shoals Boulevard, Suite 109, Newport News, Virginia. 23606-2575

E B A C   C D - 8 5    I N D U S T R I A L     D E H U M I D I F I E R 

Pure n Natural Systems  |  purennatural.com  |  1-800-237-9199

Summary of Contents for CD85

Page 1: ...Drawing TPC361 Issue 3 Date 03 10 12 CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk E B A C C D 8 5 I N D U S T R I A L D E H U M I D I F I E R Pure n Natural Systems purennatural com 1 8...

Page 2: ...5 PACKAGE CONTENTS Item Description Quantity 10293GR US Dehumidifier 1 3014338 PVC Tube 12mm I D 3M 3086101 Jubilee clip 1 TPC361 Manual 1 E B A C C D 8 5 I N D U S T R I A L D E H U M I D I F I E R P...

Page 3: ...ugh the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated by the compressor The air is therefore discharged from the deh...

Page 4: ...M3 hex head bolts Evaporator Grille Cover and Evaporator Blanking Cover are interchangeable Condenser Grille Cover and Condenser Blanking Cover are interchangeable Evaporator and Condenser covers are...

Page 5: ...Grille Cover Air into Machine Condenser Blank Cover Blocks airflow Evaporator Blank Cover Blocks Airflow Condenser Blank Cover Blocks airflow Evaporator Grille Cover Air into Machine Condenser Grille...

Page 6: ...dustrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL CD85 HEIGHT 15 75 WIDTH 23 6 DEPTH 13 5...

Page 7: ...below 80 F an even coating of frost should cover the entire evaporator coil ii If the air temperature is above 80 F frost and or droplets of condensed water should cover the entire evaporator coil F...

Page 8: ...F the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiri...

Page 9: ...mped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant compres...

Page 10: ...rant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Contact the Facto...

Page 11: ...198 1 7 Solenoid Coil 3030421 1 8 Capacitor 3030908 1 9 Humidistat 3035147 1 10 Mains Lead 3035148 1 11 Fan Motor 3040262 1 12 Fan Motor Inlet Ring 3040254 1 13 Fan Motor Capacitor 3030893 1 14 Relay...

Page 12: ...DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SECTION FOR YOUR RECORDS CLIP AND RETURN THIS CARD PLEASE NOTE WARR...

Page 13: ...Page 13 of 15 Drawing TPC361 Issue 3 Date 03 10 12 E B A C C D 8 5 I N D U S T R I A L D E H U M I D I F I E R Pure n Natural Systems purennatural com 1 800 237 9199...

Page 14: ...Page 14 of 15 Drawing TPC361 Issue 3 Date 03 10 12 E B A C C D 8 5 I N D U S T R I A L D E H U M I D I F I E R Pure n Natural Systems purennatural com 1 800 237 9199...

Page 15: ...Date 03 10 12 E B A C C D 8 5 I N D U S T R I A L D E H U M I D I F I E R Pure n Natural Systems purennatural com 1 800 237 9199 Distributed by Pure n Natural Systems Inc PO Box 1137 Streamwood IL 60...

Reviews: