CD100 OWNERS MANUAL
Drawing No. :- TPC112
Issue :-
1
Date :-
20/06/03
INSTALATION
POSITIONING:
Position the dehumidifier unit in the center of the room to be conditioned if at all possible.
However if a damp patch is particularly apparent the outlet grille should be pointed towards it.
NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have clear space around
them and not be obstructed in anyway.
WIRING:
Connect the power mains cable to a 13 Amp power supply. As follows:-
Brown
Live
Blue
Neutral
Green/Yellow Earth
(ground)
DRAINAGE:
Connect a 15mm inside diameter hose to the water outlet pipe. Secure the hose using a worm
drive clip. The hose should at no point be raised higher than the outlet pipe. Failure to observe
this requirement will result in flooding of the dehumidifier unit.
The CD100 may also be fitted with a water pump (optional), which is capable of discharging the
condensate water 30ft away from the unit. The water can, therefore, be discharged into a drain
some distance away.