20
EBA 721-05
01-04
5. Malfunctions
Danger!
Disconnect from the mains before starting
any service work or before removing the
cover. Afterwards attach the covers.
Malfunction:
Display illumination off.
Cause:
Power supply.
Remedy:
- Machine is plugged in?
- Main switch is on?
- Green overload switch (36) is pressed?
- Key switch on?
- Check the units fuse and the on-site circuit
breaker!
Malfunction:
Optical cutting line indicator does not function
after the machine has been moved to another
position.
Cause:
Phase direction wrong.
Remedy:
See "Installation and Power supply".
Malfunction:
Backgauge blocked.
Cause:
Motor is overloaded.
Remedy:
Press safety switch (37).
Malfunction:
Cut cannot be activated.
a) Cause:
Safety light beam is interrupted / dirty?
Remedy:
Remove any items and clean the sender.
b) Cause:
Measurement has not been reached correctly.
©
LED "S" does not turn off.
Remedy:
Press
again.
c) Cause:
Size under 9 cm.
Remedy:
Put the false clamp in the provided holder.