24
UXA Series Owners Manual
Bridge Mode is enabled or disabled in the AMP page for a given odd numbered Output. When enabled, the
Bridge indicator will be illuminated between the bridged channels.
When Bridged, the partner (even numbered) channel will not show any signal on the limiter meter, and the
Mute button will not operate, neither will you be able access any of its parameters for adjustment. The Amplifier
protection indicator however will still operate.
Routing
Outputs can be driven from any DSP input.
Driver
The optimal drive level may be adjusted for a given driver impedance using the Load parameter.
See
Load Matching
.
The live measured impedance value is also shown on the Driver page. Since the device can only measure
this when there is a signal, the impedance is indicated as “?” when there is insufficient signal level to perform
a measurement.
Utility Pages
Screen Contrast
The Screen page in the
“UTILITY”
section adjusts the contrast (and optimal viewing angle) of the screen from
0-100% in 1% increments.
Current Ethernet IP Address
This may be viewed in the
“IP Curr”
page of the
“UTILITY”
menu. This value cannot be edited.
IP Mode
The Ethernet IP address may be automatic
“Auto”
or may be a fixed static value
“Static”
as determined by the
“IP Mode” page of the
“UTILITY”
menu.
WARNING
– Do NOT use Static mode unless your IT system specifically requires it. Auto mode should
always be used where possible since in this mode, the Device can always be ‘discovered’ by EAW
Resolution software application. When in Static mode, the IP Address will flash on the Home screen.
Also see
Ethernet Configurations
.
IP Static
This allows the Static Ethernet IP address to be adjusted by the rotary encoders on the IP Static page of the
“UTILITY”
menu. This page will only be visible when in Static mode.
Bandwidth Units
This page of the
“UTILITY”
menu allows the Bandwidth of Parametric Equalizers to be viewed and adjusted in
either Octaves or ‘Q’.