EAW CIS300 Instruction Manual Download Page 2

2

 – CIS300

CIS300 – 

3

r

e

p

n

o

i

t

a

r

u

D

)

s

r

u

o

h

(

y

a

d

l

e

v

e

l

d

n

u

o

S

)

A

B

d

(

e

l

p

m

a

x

e

l

a

c

i

p

y

T

8

0

9

b

u

l

c

ll

a

m

s

a

n

i

o

u

D

6

2

9

4

5

9

n

i

a

r

t

y

a

w

b

u

S

3

7

9

2

0

0

1

c

i

s

u

m

l

a

c

i

s

s

a

l

c

d

u

o

l

y

r

e

V

5

.

1

2

0

1

1

5

0

1

t

e

e

f

0

5

t

a

e

v

i

t

o

m

o

c

o

L

5

.

0

0

1

1

s

s

e

l

r

o

5

2

.

0

5

1

1

t

r

e

c

n

o

c

k

c

o

r

a

t

a

s

t

r

a

p

t

s

e

d

u

o

L

Part No. 0009737  Rev. A  03/04
© 2004 LOUD Technologies Inc.  All Rights Reserved.  

1. SAFETY INSTRUCTIONS

1.1. Read Instructions — Before connecting and using the 

equipment, please read this Instruction Manual carefully and keep 

it for future reference.
1.2. HEED ALL WARNINGS — Always follow the precautions 

provided on this EAW Commercial product and in the instruction 

manual.
1.3. Water and Humidity — Do not use this EAW Commercial 

product near water; for example, in the vicinity of a bath tub or 

sink, in a damp cellar, near a swimming pool, etc.
1.4. Foreign Bodies and Liquids — Be careful not to allow any 

foreign bodies or liquids to get into this EAW Commercial 

product.
1.5. Servicing — The user should never attempt to make any 

repairs on this EAW Commercial product unless otherwise 

indicated in the instruction manual. All repairs should be made by 

qualified service technicians.
1.6. Installation — Do not install this EAW Commercial product in 

any way that is not provided for in the instruction manual.
1.7. Respect the Safety Standards — The entire sound system 

must be designed in compliance with the current standards and laws 

regarding electrical systems.
1.8. Specifications — When installing and using this EAW 

Commercial product, keep in mind the technical specifications 

indicated in the dedicated section of the manual.
1.9. Accessories — Install and use this EAW Commercial product 

only with the accessories specified by the manufacturer or 

supplied with the product.
1.10. Hearing Loss — Exposure to high sound levels can cause 

permanent hearing loss. The sound pressure level which leads 

to hearing loss varies considerably from one person to another, 

and depends on the duration of exposure. The U.S. Government’s 

2. TABLE OF CONTENTS

1. SAFETY INSTRUCTIONS ...................................................2

2. TABLE OF CONTENTS........................................................2

3. KEY FEATURES....................................................................2

4. INTRODUCTION..................................................................3

5. PRODUCT DESCRIPTION...................................................3

6. INSTALLING THE CIS300 ...................................................4

7. SPECIFICATIONS................................................................6

8. SERVICE INFORMATION ...................................................8

3. KEY FEATURES

•  Proprietary waveguide design to improve 

hi-frequency dispersion

•  Ported design for extended low-frequency 

response

•  1" soft-dome tweeter with neodymium 

magnetic motor structure

•  4" low-frequency woofer
•  Built-in 70/100V transformer with multiple 

taps

•  Transformer bypass for low-impedance 

operation (16 ohms)

•  True 2-way crossover
•  Built-in switchable high-pass filter
•  Complete assembly for quick installation
•  UL/cUL/CE listed

WARNING! This equipment has been designed to be installed 

by qualified professionals only! There are many factors to be 

considered when installing professional sound reinforcement 

systems, including mechanical and electrical considerations, as 

well as acoustic coverage and performance. LOUD Technologies 

strongly recommends that this equipment be installed only by a 

professional sound installer or contractor.

Occupational Safety and Health Administration (OSHA) has 

established the maximum sound pressure levels that can be 

with stood without causing damage, which are shown in the 

table below. According to the OSHA regulations, any exposure 

over the maximum limits indicated in the table can reduce the 

hearing capacity of a person. To prevent potentially dangerous 

exposure to high sound pressure levels, anyone subjected to such 

levels must use suitable protection. When an EAW Commercial 

product capable of producing high sound levels is being used, it 

is therefore necessary to wear ear plugs or protective earphones 

when the limits shown in the table are exceeded.
Consult the specifications provided in the instruction manual to 

know the maximum sound pressure (SPL) the speaker is capable 

of producing.

Summary of Contents for CIS300

Page 1: ... CIS300 2 Way Ceiling Monitor INSTRUCTION MANUAL ...

Page 2: ...ure to high sound levels can cause permanent hearing loss The sound pressure level which leads to hearing loss varies considerably from one person to another and depends on the duration of exposure The U S Government s 2 TABLE OF CONTENTS 1 SAFETY INSTRUCTIONS 2 2 TABLE OF CONTENTS 2 3 KEY FEATURES 2 4 INTRODUCTION 3 5 PRODUCT DESCRIPTION 3 6 INSTALLING THE CIS300 4 7 SPECIFICATIONS 6 8 SERVICE IN...

Page 3: ...tile T channels A template is also included for marking the correct cutout size The Phoenix style connector on the back of the assembly provides input and loop through connections for 70V 100V distribution systems or low impedance operation An easily accessible rotary switch on the front panel selects the appropriate tap from 3 7 watts to 30 watts A second switch allows you to select among full ra...

Page 4: ...that is provided higher density coverage the more SPL the system is capable of providing and the less variation in level as you move around the area The downside of higher density coverage of course is that more speakers are required for a given area INSTALLATION Note Observe all local and national codes when installing the CIS300 1 Cut the hole for the speaker using the supplied cutout template I...

Page 5: ...in relief screws to secure the speaker cable or flexible conduit Close the terminal cover plate 7 and tighten the locking screw 7a firmly B2 Open the terminal cover plate 7 on the back of the CIS300 Use a threaded conduit set screw coupler not supplied For 1 2 conduit use Thomas Betts Steel City model TC221 SC or UL listed equivalent1 and insert into the opening exposed by removing the strain reli...

Page 6: ... reinforce the very low frequencies use the HIGH PASS position to roll off the frequencies below 150 Hz This provides the added benefit of making more power available for the crucial mid and high frequencies If the speaker is being used in a low impedance system use the FULL RANGE 16 OHM position This bypasses the tapped transformer 6 Install the grille 1 by pressing it into place until the front ...

Page 7: ...r hanging Ring Safety loop located at rear of enclosure for attachment of load bearing safety strap Safety Agency Rating UL1480 General Signaling Fire Standard UL2043 Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air handling Spaces Inputs Outputs Removable locking connector with screw down terminals 2 input terminals and 2 loop thru terminal...

Page 8: ...hen you call You must have a Return Authorization Number in order to obtain warranty service at the factory or at an authorized service center You can also email EAW Commercial Tech Support at support eawcommercial com 2 Pack the unit in its original packaging THIS IS VERY IMPORTANT LOUD Technologies is not responsible for any damage that occurs during shipping due to non conventional packaging Or...

Reviews: