background image

2

 – CAM150 / CAM60

CAM150 / CAM60 – 

3

1. SAFETY INSTRUCTIONS

1.  Read Instructions

 — Read all the safety and operation instructions 

before operating the Component.

2.  Retain Instructions

 — The safety and operating instructions should 

be kept for future reference.

3.  HEED ALL WARNINGS

 — Follow all warnings on the Component 

and in these operating instructions.

4.  FOLLOW ALL INSTRUCTIONS

 — Follow all operating and other 

instructions.

5.  Water and Moisture

 — Do not use the Component near water 

– for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a 

wet basement, near a swimming pool, etc.

6.   Ventilation

 — This Component should be situated so that its location 

or position does not interfere with its proper ventilation. For example, 

it should not be situated on a bed, sofa, rug, or similar surface that may 

block any ventilation openings, or placed in a built-in installation such as 

a bookcase or cabinet that may impede the flow of air through ventilation 

openings.

7.  Heat

 — Locate the Component away from heat sources such as 

radiators, or other devices which produce heat.

8.  Power Sources

 — Connect the Component to a power supply only 

of the type described in these operation instructions or as marked on the 

rear panel. If using an external DC power supply or battery pack, be sure 

the voltage corresponds to the range indicated on the rear panel, and 

that it is connected with the correct polarity.

9.  Power Cord Protection

 — Route power supply cords so that they 

are not likely to be walked upon or pinched by items placed upon or 

against them, paying particular attention to cords at plugs, convenience 

receptacles, and the point where they exit the Component. 

10.  Object and Liquid Entry

 — Do not drop objects into or spill 

liquids into the inside of the Component.

11.  Damage Requiring Sevice

 — The Component should be serviced 

only by qualified service personnel when:

 

A. The power-supply cord or the plug has been damaged; or

 

B. Objects have fallen, or liquid has spilled into the Component; or

 

C. The Component has been exposed to rain; or

TABLE OF CONTENTS

1. SAFETY INSTRUCTIONS ...................................................2

2. INTRODUCTION..................................................................3

       KEY FEATURES.................................................................3

       APPLICATIONS ................................................................3

3. FRONT PANEL FEATURES .................................................4

4. REAR PANEL FEATURES....................................................5

5. THERMAL CONSIDERATIONS ..........................................8

6. CONNECTIONS ...................................................................8

7. TYPICAL HOOKUP DIAGRAM...........................................9

8. SPECIFICATIONS..............................................................10

9. SERVICE INFORMATION .................................................11

10. EAW COMMERCIAL WARRANTY ................................11

 

D. The Component does not appear to operate normally or exhibits a 

marked change in performance; or

 

E. The Component has been dropped, or its chassis damaged.

12.  Servicing

 — The user should not attempt to service the Component 

beyond those means described in this operating manual. All other 

servicing should be referred to the EAW Commercial Service Department.

13.  To prevent electric shock

, do not use this polarized plug with an 

extension cord, receptacle or other outlet unless the blades can be fully 

inserted to prevent blade exposure.

Pour prévenir les chocs électriques ne pas utiliser cette fiche polariseé 

avec un prolongateur, un prise de courant ou une autre sortie de 

courant, sauf si les lames peuvent être insérées à fond sans laisser 

aucune pariie à découvert.

14.  Grounding or Polarization

 — Precautions should be taken so 

that the grounding or polarization means of the DX-810 is not defeated. 

15. 

This apparatus does not exceed the Class A/Class B (whichever is 

applicable) limits for radio noise emissions from digital apparatus as set 

out in the radio interference regulations of the Canadian Department of 

Communications.

ATTENTION —Le présent appareil numérique n’émet pas de bruits 

radioélectriques dépassant las limites applicables aux appareils 

numériques de class A/de class B (selon le cas) prescrites dans le 

règlement sur le brouillage radioélectrique édicté par les ministere des 

communications du Canada.

WARNING! This equipment has been designed to be installed 

by qualified professionals only! There are many factors to be 

considered when installing professional sound reinforcement 

systems, including mechanical and electrical considerations, as 

well as acoustic coverage and performance. EAW Commercial 

strongly recommends that this equipment be installed only by a 

professional sound installer or contractor.

Part No. 0010169  Rev. A  02/04
© 2004 LOUD Technologies Inc.  All Rights Reserved.  

CAUTION    

AVIS

RISK OF ELECTRIC 

SHOCK • DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER-SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

ATTENTION: POUR EVITER LES RISQUES DE CHOC

ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE.  AUCUN

ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER.  CONFIER

L'ENTRETIEN AU PERSONNEL QUALIFIE.

AVIS: POUR EVITER LES RISQUES D'INCENDIE OU

D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE 

A LA PLUIE OU A L'HUMIDITE

   The lightning flash with arrowhead symbol within an equilateral triangle is 

intended to alert the user to the presence of uninsulated "dangerous voltage" 

within the product's enclosure, that may be of sufficient magnitude to constitute 

a risk of electric shock to persons.

   Le symbole éclair avec point de flèche à l'intérieur d'un triangle équilatéral est 

utilisé pour alerter l'utilisateur de la présence à l'intérieur du coffret de "voltage 

dangereux" non isolé d'ampleur suffisante pour constituer un risque d'éléctrocution.

   The exclamation point within an equilateral triangle is intended to alert the user 

of the presence of important operating and maintenance (servicing) instructions 

in the literature accompanying the appliance.

   Le point d'exclamation à l'intérieur d'un triangle équilatéral est employé pour 

alerter les utilisateurs de la présence d'instructions importantes pour le fonction-

nement et l'entretien (service) dans le livret d'instruction accompagnant l'appareil.

Summary of Contents for CAM150

Page 1: ...CAM150 CAM60 Integrated Mixer Amplifiers INSTRUCTION MANUAL 2004 LOUD TECHNOLOGIES INC EAW IS A REGISTERED TRADEMARK OF LOUD TECHNOLOGIES INC CAM150 MIXER AMPLIFIER...

Page 2: ...or other outlet unless the blades can be fully inserted to prevent blade exposure Pour pr venir les chocs lectriques ne pas utiliser cette fiche polarise avec un prolongateur un prise de courant ou u...

Page 3: ...lume adjustment is provided with a small monitor trim control on the rear panel Output modes include 4 constant impedance and 25 V 70 V and 100 V constant voltage The smart output stage is fully prote...

Page 4: ...er level and the input levels to average settings not too high and not too low For example if you find you have to turn the master volume up high then the input level controls might be set too low If...

Page 5: ...trols the volume of any signals connected to the TELEPHONE PAGING 10 input terminals Adjust it to suit your taste so any pages are heard clearly Turn this down if you are not using these input termina...

Page 6: ...making the connections The five output terminals are labeled COM 4 25 V 70 V and 100 V CONSTANT IMPEDANCE To connect a speaker directly connect the COM terminal to the negative post of your speaker an...

Page 7: ...wn from the DC supply Note The unit will not charge the battery so you should have a dedicated charging system Note also that when running on DC power the output is lower than when running on AC power...

Page 8: ...k ears are provided to allow the unit to be fitted within a standard 19 rack Remove two front screws from each side and securely fit each rack ear in place The unit still needs to be supported underne...

Page 9: ...CAM150 CAM60 9 7 TYPICAL HOOKUP DIAGRAM...

Page 10: ...rcial continually engages in research related to product improvement new materials and production methods Design refinements are introduced into existing products without notice as a routine expressio...

Page 11: ...end user installation site Loudspeakers 5 years Active Electronics 5 years Accessories 2 years What Is Covered Defects in workmanship and materials and against malfunctions EAW Commercial distributors...

Page 12: ...ies Inc Company EAW Commercial One Main Street Whitinsville MA 01588 USA TEL toll free within US Canada 888 337 7404 TEL outside US 425 892 6503 FAX 425 485 1152 www eawcommercial com 2004 LOUD Techno...

Reviews: