background image

12

Installation instructions for YHH30B CCTV camera station

English

  

  

  

EATON 

TM378 ISSUE A JUly 2020 

www.eaton.com 

Platform (top view)

Platform (side view) 

Platform(bottom view)

Figure 8. YHZ-F1 semi-fixed platform

Summary of Contents for YHH30B Series

Page 1: ...era Station Ex Marking II 2G Ex db II C T5 Gb normal version or Ex db op pr IIC T5 Gb optical fiber version II D Ex tb IIIC T95 C Db normal version or Ex tb op pr IIIC T95 C Db optical fiber version Certificate numbers Presafe 19 ATEX 15006X IECEx PRE 19 0070X ...

Page 2: ...e definition Connect the cables according to the requirement indicated in the Instruction Manual or fault may occur Protect the flame proof joint in maintenance avoid any metal fragment or other abrasive substances getting inside the internal chamber No disassembly or modification allowed 2 Environmental protection Components of the products made by our company may pollute the environment such as ...

Page 3: ...3 Fiber optic cable processing 8 3 4 Installation of protective shield and cylinder 8 3 5 System connection 8 3 6 Install camera to platform 9 3 7 Install camera to fixed support 9 3 8 Flame proof joint protection 9 3 9 Grounding 9 3 10 Camera Time settings 9 4 0 Ex structure instruction 9 5 0 Troubleshooting 10 6 0 Transportation and storage 10 7 0 Mounting accessories 11 8 0 Quality guarantee 13...

Page 4: ...n the optical fibre must be connected and protected according to the guidance in the instruction manual to meet the requirements of IEC 60079 28 Essential Health and Safety Requirements Essential Health and Safety Requirements EHSRs are covered by the standards listed at item 9 2 0 Technical data 2 1 Type and model Second stage Design code Ex product code H stand for protective shield Company code...

Page 5: ...ension Figure 1 External dimensions of YHH30B 2 8 Installation size Figure 2 Fixing holes at the bottom of the camera 2 9 Wiring The product has the following wiring methods please select one of the wiring methods according to the purchased specifications AC24V or AC220V input Network video signal network cable output ...

Page 6: ... instructions for YHH30B CCTV camera station English EATON TM378 ISSUE A July 2020 www eaton com AC24V or AC220V input Network video signal coaxial cable output AC24V or AC220V input Network video signal fiber output ...

Page 7: ...7 Installation instructions for YHH30B CCTV camera station English EATON TM378 ISSUE A July 2020 www eaton com Power Over Ethernet ...

Page 8: ...above 90 C 3 3 Fiber optic cable processing This product does not provide an output cable Users using the optical signal output version please weld the incoming fiber and the fiber jumper provided by our company with a fiber fusion splicer The welding place needs to be protected by a fiber protection tube and placed in the fiber protection bracket As shown below Figure 3 The insulation fiber remov...

Page 9: ...he flame proof joint in installation operation maintenance of this product no knock or scratch allowed 3 9 Grounding Internal and external grounding shall be well connected and reliable 3 10 Camera Time settings During product use the camera needs to reset the time after each power outage restart 4 0 Ex structure instruction The maximum surface temperature will no more than 80 C in normal operatio...

Page 10: ...of power supply check the power supply self handle open circuit of signal wire check the signal wire self handle damaged camera replace the camera contact the manufacturer damaged lenses replace the lenses contact the manufacturer 6 0 Transportation and storage The packaged product can be delivered in all modes of transportation but without exposure to direct rain or snow it can be stored for one ...

Page 11: ...11 Installation instructions for YHH30B CCTV camera station English EATON TM378 ISSUE A July 2020 www eaton com 7 0 Mounting accessories Mounting accessories order needed Figure 7 YHZ B20 support ...

Page 12: ... Installation instructions for YHH30B CCTV camera station English EATON TM378 ISSUE A July 2020 www eaton com Platform top view Platform side view Platform bottom view Figure 8 YHZ F1 semi fixed platform ...

Page 13: ...y Thunder or other force majeure natural disasters If any other contracts between clients and us exist we will follow the promise or regulation strictly 9 0 Company statements Cooper Yuhua Changzhou Electric Equipment Manufacturing Co Ltd reserves the right to the interpretation of the modification of product design and specification without notice This Instruction Manual is Cooper Yuhua Changzhou...

Page 14: ... package of drying agent is provided with accessories Put the drying agent inside the chamber after it s well installed and wired The place of drying agent put shall be away from the transmission element or electrical connection zone and difficult to slip to other places avoid any connection fault or transmission fault caused by drying agent ...

Page 15: ...the content of the poisonous harmful substances or elements in the component homogeneous material is lower than the limit specified in the standard 2 Symbol means the content of the poisonous harmful substances or elements in the component some certain homogeneous material is more than the limit specified in the standard SJ T11363 2006 Leakage or mutation of this poisonous harmful substances or el...

Page 16: ...based on the similarities and dissimilarities between product offerings It is not intended to replace specific product literature for Eaton products Information contained in this literature about other manufacturers product is from written material and or published or made available by the manufacturers CONFIDENTIAL For internal use only by Eaton and authorized distributors This information is int...