KEY FEATURES
•
Completely protected outputs (thermal and
overcurrent)
•
Reverse polarity protection
•
Up to 11 inputs, depending on model
•
Up to 2 outputs, depending on model
•
Programmable via USB
•
Two CAN ports
•
Sleep input for improved power management
4.0
SAFETY CONSIDERATIONS
Please note: These instructions are intended for use by a
competent programmer, electrician, technician or engineer. These
instructions should be read and kept as a reference
prior to display installation and use. Incorrect operation of
the display can present a significant threat to both individuals
and equipment. In the event of a break down, do not attempt
to repair the display as there are no user serviceable parts
inside the enclosure. Any evidence of tampering will invalidate
the warranty.
5.0 APPLICATION
This operating and installation manual should be
used in conjunction with the online help provided
with the Pro-FX Control 1.1 development
environment. Together, this information should
form a basis for the simple configuration of the
display and the creation of programs specific to your
application needs. The correct operation and function
of the display is dependent on the program that is
created and ultimately downloaded to the hardware,
therefore extensive testing is required. Customers
programming the display possess the responsibility
of ensuring that the display performs as intended.
Please note: These displays require the installation of appropriate
firmware and a hardware-specific description file and libraries
before initial use in the application environment.
6.0
HARDWARE DESCRIPTION
The Eaton VFX product line consists of two display
models, offered in 4.3” and 7” sizes (VFX40m,
VFX70m). Each of these units are designed to
function over an extended operating range of supply
voltage, from 6 – 36 VDC supply.
The two integrated CAN ports support CAN Layer 2,
SAE J1939 and CANOpen. The first CAN port also
has a software configurable termination.
USB connection provides for updates via a USB flash
drive or a USB Ethernet adapter kit. The VFX40m and
VFX70m each have a unique number of I/O.
The unit shown above is the VFX40m.
The I/O for the VFX40m is as follows:
•
1 USB
•
2 CAN Serial Ports – J1939/CANOpen
•
8 Button Illuminated Keypad
•
1 Power Input
•
1 Ignition Input
•
1 Digital Output
•
1 Analog Input
•
Video – Optional