Code plates are provided to prevent insertion of 
1200/2000 amp device into 3000 amp compartment and 
vice-versa. Type VCP-W manual grounding and test 
devices are also available with either the upper or the 
lower terminals only. Devices of the same rating with 
only the upper terminals or with only the lower terminals 
are coded to make them non-interchangeable by the 
addition of an overlay code plate 8243A53H01 in the 
breaker compartments. 

1-2 OPERATION

WARNING

READ AND UNDERSTAND THESE INSTRUCTIONS 
BEFORE ATTEMPTING TO USE THIS DEVICE. 
IMPROPER USE CAN RESULT IN DEATH, BODILY 
INJURY AND/OR PROPERTY DAMAGE. 

The following general safe practices are 
recommended: 

Store the device in a clean, dry area free from
dust, dirt, moisture, etc.

Keep all insulating surfaces, which include
primary support insulation and insulation
barriers, clean and dry.

Check all primary circuit connections to make
certain that they are clean and tight.

Permit only authorized trained personnel to use
this device.

Take extreme care while using this device to
avoid contacting “Live” or “Hot” (energized)
terminals.

Correctly identify line and bus terminals for
the breaker compartment before using this
device.

Check for correct code plate(s) on the device.
Do not attempt to force the device into the
compartment.

The grounding of either upper or lower terminals is 
accomplished by connecting cables (provided with the 
device) from either the upper or the lower terminals to 
the device ground connection. Cable testing or “phasing 
out” testing may be accomplished by connecting suit-
able test equipment, as required to the terminals.

Summary of Contents for VCP-W

Page 1: ... UNIQUE APPLICATION AND VAST VARIETY OF SYSTEM USER REQUIREMENTS SPECIFIC SAFE OPERATING PROCEDURES FOR THE USE OF THIS DEVICE MUST BE DEVELOPED BY THE USER 1 1 DESCRIPTION The device consists of a drawout element that can be inserted into a circuit breaker compartment in the same manner as a type VCP W circuit breaker It includes six terminals and ground bus connections Each terminal is isolated ...

Page 2: ...evice in a clean dry area free from dust dirt moisture etc Keep all insulating surfaces which include primary support insulation and insulation barriers clean and dry Check all primary circuit connections to make certain that they are clean and tight Permit only authorized trained personnel to use this device Take extreme care while using this device to avoid contacting Live or Hot energized termi...

Page 3: ...I L 3778A74H01 Pa g e 3 Effective 11 97 Figure 2 Standard Device ...

Page 4: ...P a g e 4 I L 3778A74H01 Effective 11 97 Figure 3 Device With Bails ...

Page 5: ...I L 3778A74H01 Pa g e 5 Effective 11 97 Figure 4 Standard Device Upper ...

Page 6: ...P a g e 6 I L 3778A74H01 Effective 11 97 Figure 5 Standard Device Lower ...

Page 7: ...I L 3778A74H01 Pa g e 7 Effective 11 97 Figure 6 Device With Bails Upper ...

Page 8: ...P a g e 8 I L 3778A74H01 Effective 11 97 Figure 7 Device With Bails Lower ...

Page 9: ...I L 3778A74H01 Pa g e 9 Effective 11 97 Figure 8 Code Plate Legend ...

Page 10: ...P a g e 10 I L 3778A74H01 Effective 11 97 ...

Page 11: ...I L 3778A74H01 Pa g e 11 Effective 11 97 ...

Page 12: ...P a g e 12 I L 3778A74H01 Effective 11 97 ISI Style 3778A74B Printed in U S A Eaton 1000 Cherrington Parkway Moon Township PA 15108 4312 ...

Reviews: