23
SONIX
TM
Hmi-26 Technical Manual
SONIX HMI26 TECHNICAL MANUAL
TM375 / A June 2022 www.eaton.com
Option
Setting
Notes
Multi Zone Mode
Disabled
Not needed for this configuration
Default Key List Map None
No zoning will be actioned on PTT without
prior selection
Table 15 - Zoning example 2 - Other configuration
5.6.5 Advanced zone map
This is a more advanced zoning set up, with multiple
zones and an all-call.
5.6.5.1 Requirements
Button
Action
Zoning
Zone button 1
Process Areas
2,3,4,5
Zone button 2
Upper Decks
2,3,5
Zone button 3
Forward Deck
2
Zone button 4
Main Deck
3
Zone button 5
Off-loading
4
Zone button 6
Heli-deck
5
Zone button 7
Engine Room
6
Zone button 8
All-Call
All
Zone button 9
Accommodation
1
PTT
Process areas
2,3,4,5
Table 16 - Zoning example 3 - Requirements
5.6.5.2 Configuration
Zone button
Setting
Notes
1
31
1+0+2+4+8+16 = 31: Zones 2[2], 3[4], 4[8], 5[16]
2
15
1+0+2+4+0+16 = 23: Zones 2[2], 3[4], 5[16]
3
2
Zone 2
4
3
Zone 3
5
4
Zone 4
6
5
Zone 5
7
6
Zone 6
8
31
All-call
9
1
Zone 1
10
32
Disabled
11
1
1+0+0+0+0+0 = 1: Zones 6-10 NOT selected
12
1
1+0+0+0+0+0 = 1: Zones 6-10 NOT selected
Table 17 - Zoning example 3 - Zone Button Configuration
Option
Setting
Notes
Multi Zone Mode
Enabled
Buttons 1 & 2 are multi-zone buttons
Default Key List Map
1
Zoning required matches button 1
Table 18 - Zoning example 3 - Other configuration
5.6.6 Large amplifier count zone map
This is a more advanced zoning set up, with 4 acoustic
zones and an all-call, but some of the zones are so big
Sonix needs to use multiple zone numbers to support
enough amplifiers. This is distinct from All-Call, which
activates All zones without exception. In order to achieve
this zone map, Multi Zone mode must be enabled
allowing buttons 1 and 2 to be available to activate
multiple zones.
5.6.6.1 Requirements
Button
Action
Zoning
Zone button 1
Process Areas
2,3,4,5,6 – Need to use multiple
Sonix zones to support enough
amplifiers
Zone button 2
Upper Decks
7,8
Zone button 3
Accommodation
1
Zone button 4
Engine Room
9
Zone button 5
All-Call
All
PTT
All but accommodation 2,3,4,5,6,7,8,9
Table 19 - Zoning example 4 - Requirements
5.6.6.2 Configuration
Zone button
Setting
Notes
1
31
1+0+2+4+8+16 = 31: Zones 2[2], 3[4], 4[8], 5[16]
2
1
1+0+0+0+0+0 = 1: Zones 1-5 NOT selected
3
1
Zone 1
4
9
Zone 9
5
31
All-call
6-10
32
Disabled
11 [Button 2]
7
1+0+2+4+0+0 = 7: Zones 7[2], 8[4]
12 [Button 1]
2
1+1+0+0+0+0 = 2: Zones 6[1]
Table 20 - Zoning example 4 - Zone Button Configuration
Option
Setting
Notes
Multi Zone Mode
Enabled
Buttons 1 & 2 are multi-zone buttons
Default Key List Map 1,2,4
Zoning required matches button 1 + 2 + 4
Table 21 - Zoning example 4 - Other configuration
ote:
N
Buttons 11 and 12 are now NOT available for zone selection and
pressing will have no effect but are still available for MS12 message
initiation.