background image

SONIX

TM 

Hmi-26 Access Panel

Sonix

TM

 Hmi-26  Technical Manual

Summary of Contents for SONIX Hmi-26

Page 1: ...SONIXTM Hmi 26 Access Panel SonixTM Hmi 26 Technical Manual...

Page 2: ...d including Warranties of fitness for a particular purpose or merchantability other than those Specifically set out in any existing contract between the parties Any such contract states the entire obl...

Page 3: ...to the loudspeaker and generates feedback 2Mx Sonix 2Mx Central controller Amp 350 d Sonix 350 W Power Amplifier with 100 V line output Eol1 Sonix Remote End of Line unit Eol8 Sonix Amplifier to 100...

Page 4: ...3 3 Installation and connectivity 10 3 3 1 Data and Audio connections 10 3 3 2 Local Mute Local Attenuate unit 10 3 3 3 Local Power 11 4 UNIT OPERATION 12 4 1 Data communications 12 4 2 System Status...

Page 5: ...Remote initiation 20 5 CONFIGURATION 21 5 1 Hardware configuration links 21 5 2 Solo connected access panels 21 5 3 Fully connected access panels 21 5 4 Unit ID 21 5 4 1 Ping set Set new Unit ID 21 5...

Page 6: ...BUTTON VALUE MAP 25 TABLE 8 MULTI ZONE MODE BUTTON DISTRIBUTION 25 TABLE 9 MULTI ZONE BUTTON VALUE CALCULATION 26 TABLE 10 ZONING EXAMPLE 1 REQUIREMENTS 26 TABLE 11 ZONING EXAMPLE 1 ZONE BUTTON CONFIG...

Page 7: ...TIONS 10 FIGURE 6 LOCAL DC POWER CONNECTIONS 10 FIGURE 7 STATUS REPORTING LEDS 12 FIGURE 8 ALARM ACTIVATION AND CONTROL BUTTONS 14 FIGURE 9 ALL CALL VS ZONED ALARMS 14 FIGURE 10 ZONED ALARM ACTIVATION...

Page 8: ...lation in both safe area or potentially explosive environments using latest protection philosophies including EExe d i m and p to ensure the highest levels of safety whilst increasing operational feat...

Page 9: ...ation including system activity Active alarms Active zones Active broadcast System health with fault buzzer to attract operator attention Local speaker Mute Attenuate control LED Lamp test Microphone...

Page 10: ...pin without any crossover A side PA GA ASSIGNMENT CONNECTION 2off Twisted pair individual and overall screen 1 5 mm to 2 5 mm max ferruled SWA SWB Audio 1 J3 1 Audio 1 J3 2 Data 1 J3 3 Data 1 J3 4 Scr...

Page 11: ...uled 5 V J9 3 J10 3 5 V J9 4 J10 4 Attenuate Solid to 1 5 mm Stranded to 0 5 mm max ferruled 5 V J9 5 J10 5 5 V J9 6 J10 6 Table 3 Mute Attenuate cable connection details 3 3 3 Local Power For install...

Page 12: ...reset The Health indicator has no configurable options 4 2 2 Busy Indication of activity on the PA GA system None System is idle Green System is active Slow flashing AB active Green 0 7 Hz Fast flashi...

Page 13: ...e Alarm is active on the system and has been activated from this access panel Flashing Alarm is active on the system but was Orange activated by a different source 0 5 Hz ote N The LED will still illu...

Page 14: ...led in configuration to prevent the access panel from sending the alarm cancel signal use this for access panels located in less secure areas The LED shows the following status None Alarm Cancel is NO...

Page 15: ...ttons will also follow any pre selected zone buttons and will NOT be All Call as might be expected Figure 12 Available zone buttons The associated LEDs with each zone button display the status of the...

Page 16: ...tact your local Eaton representative 4 4 5 1 VU meter The approximate volume of the microphone input audio is displayed in real time on the VU meter found on the right hand side of the Hmi 26 unit Ope...

Page 17: ...a maximum transmit time called PTT Timeout When this setting is active the access panel will automatically cancel the active PTT session if it exceeds the time set in the configuration Valid values ra...

Page 18: ...dcasts if they are not the one active on the system 4 4 8 1 Attenuate output Additionally the Hmi 26 has a second output intended to control a local speaker attenuate The attenuate feature is provided...

Page 19: ...e 19 Fault Acknowledge button The Fault Acknowledge button found bottom right of the Hmi 26 unit is used by the operator to indicate the fault has been observed Pressing the button once will mute the...

Page 20: ...ic This has the practical application that an Engineer s alarm can be overridden by routine speech broadcasts from another source Emergency speech from the Engineers Panel is positioned like a normal...

Page 21: ...should be the same for both sides Zoning Alarms Available buttons Fault monitoring 5 4 Unit ID Each Hmi 26 access panel on a system needs to have a unique identifier called a Unit ID or number This n...

Page 22: ...button Table 8 Multi Zone mode button distribution Zone Value Zone Button 1 Value Button 2 Zone Button 12 Value Button 11 1 1 1 1 32 2 2 3 4 4 8 5 16 6 1 1 1 32 7 2 8 4 9 8 10 16 11 30 Not available...

Page 23: ...Zoning required matches button 1 Table 18 Zoning example 3 Other configuration 5 6 6 Large amplifier count zone map This is a more advanced zoning set up with 4 acoustic zones and an all call but som...

Page 24: ...for correct unit Power source for Hmi 26 access panel can be rack powered Procedure for programming units is as follows 1 Visual inspection of unit to ensure no damage to PCB and components 2 Connect...

Page 25: ...aton and SONIX are registered trademarks All other trademarks are property of their respective owners Changes to the products to the information contained in this document and to prices are reserved s...

Reviews: