background image

Page 2 

Do not site the siren: 

  Within 1m of large metal structures 

such as metal doors or frames, water 
tanks, fridges and cars. 

  Within 1m of mains wiring, power 

distribution units or metal pipes. 

  Inside metal enclosures. 

  Near high-voltage equipment, or near 

electronic equipment such as 
computers, photocopiers or other radio 
devices. 

Step 2 

– Open the Lid of the Siren 

1.  With the siren not yet fixed to the wall, 

open the hinged cover that gives 
access to the lid-retaining screw (see 
Figure 2). 

2.  Loosen the screw and open the lid. 

Step 3 

– Configure the Siren Jumpers 

1.  Remove the link/terminal cover (see 

Figure 2) by pushing the two retaining 
tabs to the side of the unit while lifting 
the cover. 

2.  Set all jumpers in the siren to the 

required positions (see

 Quick 

Reference 

on page 3). 

Step 4 

– Teach the Control Unit the 

Identity of the Siren 

1.  If not already done, power-up the 

control unit. If the siren communicates 
through a radio expander, add the radio 
expander. 

2.  Place the siren next to a keypad and also 

within range of the radio expander or 
control unit that it communicates with. 

3.  Select: 

Installer Menu 

– Detectors/ 

Devices 

– External Sirens – Radio 

Sirens 

– Add/Del Siren – <expander> – 

<siren address> 

– Activate Siren 

Tamper

. Keep this option displayed 

while you carry out the next step. 

4.  Connect both batteries in the siren (see 

Figure 1). The control unit should 
discover the siren and you should see 
"Siren added". If you do not see this, try 

again: disconnect the batteries, wait 30 
seconds and reconnect. 

 

 

 

 

 

5. 

Disconnect the batteries

 (to prevent a 

risk of the siren self-activating). Do not 
exit the Installer menu. 

Step 5 

– Attach the Siren to the Wall 

1.  Position the siren against the wall using 

the built-in spirit level to assist levelling, 
and mark all four fixing points. 

2.  Drill and plug the fixing points using the 

screws and plugs provided. 

3.  Pass wiring through the cable-entry 

hole. 

4.  Screw the siren to the wall. Use the 

spirit level and revolving guides to 
correct any misalignment. 

Step 6 

– Power-Up the Siren 

Note: 

The sounder should not activate 

during the following process. 

However, be 

prepared in the event that it does 
activate; make sure that any very loud 
noise produced cannot cause a fall.

 

1.  Re-connect the batteries. 

 

The siren should power up in "silent 
startup" mode, which is indicated by the 
left-hand comfort LED remaining solidly 
lit. 

2.  The right-hand comfort LED indicates 

the state of the comfort LEDs. ON = 
comfort LEDs enabled; OFF = comfort 
LEDs disabled. To toggle the comfort 
LEDs on/off, press the tamper switch 
five times. 

3.  Re-fit the jumper/terminal cover, close 

the lid, tighten the lid-retaining screw 
and close the screw cover. 

Figure 1: Battery 
Connector 

Summary of Contents for SDR-REXT

Page 1: ...er quiet maintenance mode Battery voltage monitoring Lid and rear tamper detection Selectable cut off timer Choice of siren tones Impact resistant polycarbonate construction Table of Contents Installi...

Page 2: ...displayed while you carry out the next step 4 Connect both batteries in the siren see Figure 1 The control unit should discover the siren and you should see Siren added If you do not see this try agai...

Page 3: ...r Details for further information Figure 3 Jumpers and Connections Hinged cover for lid retaining screw Link terminal cover Cover retaining tab pull tab each side to release cover Tamper switch Spirit...

Page 4: ...System Options Jamming option can be set to Off Fault or Tamper Jamming is not reported if Off is selected Please refer to the Engineering Guide for additional information Control units expanders and...

Page 5: ...siren for correct operation check the tamper switch and for any signs of water or insect ingress and clean as necessary Replace the batteries every two years or as advised by the control panel see bel...

Page 6: ...teries is SDR R BAT1 Battery Life Typically 2 years Weight 1 2kg without batteries Operating Temperature 25 C to 60 C Max Relative Humidity 95 Dimensions 290mm h x 277mm w x 80mm d SIMPLIFIED EU DECLA...

Page 7: ...Page 7 NOTES...

Page 8: ...NTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence stri...

Reviews: