126
Eaton RF-System - Help
© 2015 Eaton Electrical Group
As you can see in the picture for every day you can set 3 different time spans with different
operation modes. Please note, if you would like to set a time over midnight you have to separate it
in 2 time spans
One before midnight and one after midnight.
The operation mode outside of a time span is always „Night“.
Motion detector
The motion detector detects movement and sends RF-commands to its assigned devices.
Every actuator (switching actuator, dimming actuator, shutter actuator, analogue actuator) can be
controlled by the motion detector and information can be sent to the Room Manager, Home
Manager and the Comm.-interface.
Channel A is the detection output and sends depending on the ambient light value a ON command
if movement is detected and after a adjustable time when there is no new movement the channel
sends the OFF command.
Channel B is immediately activated independent from the ambient light level and after a fix time of
120 seconds automatically deactivated if no more movement is detected in this time span.
Channel B mainly is used for alarms.
The activated time will be retriggered if new movement is detected within this time span.
By using the DIP-switches in the device Channel A and B can be activated and deactivated
separately.
Also the light value range (Night, Dawn, Day & Night) can be set by the DIP-Switches.
Movement is only detected if the actual light value is within the set light level.
Summary of Contents for RF System 2.42
Page 1: ...Eaton RF System 2 42 Manual...
Page 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...
Page 193: ...193 Eaton RF System 2015 Eaton Electrical Group...
Page 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...
Page 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...
Page 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...
Page 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...
Page 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...