1.5.1

 

LAN-Connections 

1.5.1.1

 

Default Version one LAN Connection with a Cable Gland 

The telephone has in the default version one internal LAN-connection with a Cable Gland. 
For  the  connection  a  LAN  cable  must  be  pulled  through  the  Cable  Gland.  Inside  the 
phone the female LAN connection from AMP NETCONNECT (TE Connectivity) has to be 
pressed  on  the  cable  (Refer  to  chapter  1.4  beginning  on  page  8).  A  female  LAN  cable 
connector belongs to the as-delivered condition. With the inside the phone existing little 
LAN connection cable, the LAN can be connected with the phone. 

The  LAN  delivery  can  be  available  with  PoE  (Power  over  Ethernet).  Alternatively  the 
phone can be supplied with power external.  

All not used cable feed through have to be closed with sealing plugs.  

 

Caution 

You  can  use  PoE  (Power  over  Ethernet)  or  an  external  connection  to  supply  the 
ResistTel IP2 / IP152 with power.  

Don’t use both at the same time, to prevent damage to the equipment. 

 

1.5.1.2

 

Version  with  Switch  LAN  Module  with  two  LAN 

Connections with Cable Glands 

The telephone has in this version two internal LAN-connections with a Cable Gland. For 
the connection the LAN cable must be pulled through the Cable Gland. Inside the phone 
the female LAN connection from AMP NETCONNECT (TE Connectivity) has to be pressed 
on the cable (Refer to chapter 1.4 beginning on page 8). A female LAN cable connector 
belongs  to  the  as-delivered  condition.  With  the  inside  the  phone  existing  little  LAN 
connection cable, the LAN can be connected with the phone. 

The  LAN1  delivery  can  be  available  with  PoE  (Power  over  Ethernet).  Alternatively  the 
phone can be supplied with power external.  

The LAN2 delivery doesn’t support PoE. Also it can’t be used to connect a phone directly, 
which should be powered with PoE. 

All not used cable feed through have to be closed with sealing plugs. 

Summary of Contents for ResistTel IP2/IP154

Page 1: ...FHF BA9710 09 17 V8 V9 Explosion proof and weatherproof VoIP telephones...

Page 2: ...res and the mounting and installation instructions are part of this document For the complete configuration and operating of all features the knowledge of the complete manual is necessary The complete...

Page 3: ...ode to Headset Mode 20 72 2 1 Changeover from Headset Mode to Headset Mode with Open Listening 20 82 2 1 Changeover from Headset Mode with Open Listening to Headset Mode 20 92 2 1 Changeover from Head...

Page 4: ...4 1 VoIP Telephone ResistTel IP2 IP152 and ExResistTel IP2 IP154 1 1 Keypad Figure 1 Keypad of the VoIP Telephone...

Page 5: ...only be adjusted during a call long The asterisk key also serves as a mute key During a call a longer press switches the microphone off or on Digit keys for entering phone numbers The asterisk and ha...

Page 6: ...ration is displayed in the first line The middle lines display special information relating to the condition The date time and registration status is displayed in the last line 1 4 2 3 5 Torsten 72 06...

Page 7: ...all diversion activated Handset activate Headset active Telephone locked Calling number transmission locked 3 Own call number E 164 4 Called party Calling party Unknown number name unresolved number D...

Page 8: ...r for cable mounting Optional relay module Accessories optional Headset with connection cable and attachment of the bracket connecting cable RJ45 RJ45 LAN female connector for cable mounting Cable gla...

Page 9: ...e glands have to be considered Prior to assembly check cover seal for tightness Using the plug connector 7 plug the ribbon cable onto the pin contact strip 8 in the upper part of the housing Attach th...

Page 10: ...10 Figure 6 Set View Figure 7 Inside View of Telephone upper Part...

Page 11: ...11 Figure 8 Inside View of Telephone lower Part Figure 9 Connection Diagram with Single LAN Module 1 2 3 4 5 6 7 8 9 10 11 12 13 X 1 0 X11 X1 X2 X3 X4 X5 X6 LAN PoE X7 X 8 X 1 2 X 9...

Page 12: ...onal X10 Amplifier Module optional X11 Handset X12 Relay Module optional LAN PoE LAN with PoE LAN Link single LAN Module LAN1 PoE LAN1 with PoE LAN Link Switch LAN Module LAN2 PC LAN2 PC Link Switch L...

Page 13: ...an external connection to supply the ResistTel IP2 IP152 with power Don t use both at the same time to prevent damage to the equipment 1 5 1 2 Version with Switch LAN Module with two LAN Connections w...

Page 14: ...rnal power connection will be used you must not use PoE at the LAN connection 1 5 3 Relay Connection The phone can be build up with a relay module with two relays with a single changeover switch optio...

Page 15: ...th mains both SELV or both TNV circuits It is not permissible to connect different types of circuits to these relays 1 5 4 Other Terminals The terminals 1 4 are for connecting a headset A detailed des...

Page 16: ...key left Delete character in front of cursor Clearing key Pressing and holding the numeric key activates the character mode Refer to chapter 2 1 5 Input of Characters and Special Characters beginning...

Page 17: ...ns on this level after the call The Vol indicator shows the current value see Figure 13 You can increase the ringer volume level by pressing the key You can reduce the ringer volume level by pressing...

Page 18: ...H 323 names The is removed before dialling however 2 1 5 Input of Characters and Special Characters You can enter any Western European characters in accordance with ISO 8859 1 using the keypad The as...

Page 19: ...is connected and configured 4 Headset mode At headset mode the call will be operated with the headset 5 Headset mode with open listening At headset mode with open listening the call will be operated...

Page 20: ...ngeover from Hands Free Mode to Headset Mode To change from hands free mode to headset mode you have to press the headset key Key long longer than a second and then the loudspeaker key 2 2 7 Changeove...

Page 21: ...r rejecting calls If you would like to answer the call you have different possibilities Lift the handset Press the loudspeaker key Press the headset key Key long longer than a second and then the loud...

Page 22: ...handset back on its rest handset mode Press the key All modes Press the loudspeaker key hands free mode Press the headset key Key long longer than a second and then the loudspeaker key headset mode 2...

Page 23: ...Indirect Dialling If you use the cursor keys to select the menu item Call as User and then press the key the menu User List appears see manual Now the User can be changed prior to dialling The change...

Page 24: ...last is displayed see Figure 18 Success connected not connected The symbol on the display indicates that there has been a successful call A not connected call will be displayed without a symbol The sy...

Page 25: ...display indicates that there has been a call The symbol on the display indicates that there has been a redirected call The symbol on the display indicates that there has been a transferred call The sy...

Page 26: ...hold can t hear the second call The hold function is also needed to switch or transfer a call Torsten 72 Peter 36 Torsten 72 Please dial 06 01 10 14 40 0 22 Figure 21 Holding a Call 1 Press the key s...

Page 27: ...3 9 Transferring a Call You are making a call and would like to transfer it to another party Torsten 72 Peter 36 Torsten 72 Thomas 70 06 01 10 14 40 0 22 Figure 23 Transferring a Call 1 Press the key...

Page 28: ...24 Transferring a Call Directly 1 Press the key long during a call 2 You will be left The actual connection will not be displayed 3 Dial the call number of your choice 4 Press the key short or key 5...

Page 29: ...to the initiated conference is now on hold again and the previously active call is active once again If you end the conference with pressing the key short twice the call put on hold prior to the init...

Page 30: ...Glands 267 x 225 x 132 mm Weight default version ca 5 0 kg Display 182 x 64 pixel Field of view ca 78 mm x 26 mm Keypad Metal keypad with ice protection 21 keys with ABC marking Hook switch Reed cont...

Page 31: ...to the Steering Magnetic compass 0 70 m reduced 0 35 m For the operation on the bridge of the ship the maximum prescribed ringer volume of 75 85 dB A must not be exceeded Therefore the factory setting...

Page 32: ...0 Fax 49 208 82 68 286 Mail info fhf de www fhf de Orders fhf orders eaton com Requests fhf sales eaton com Support fhf support eaton com Eaton s Crouse Hinds Business 1201 Wolf Street Syracuse NY 132...