IM0284.Revision 5 05/17
Page 1 of 2
3. Safety Instructions
This product should be installed, inspected, and maintained by a qualified
electrician only, in accordance with national regulation, including the relevant
standard and, where applicable. The national safety rules and regulations for
prevention of accidents and the following safety instructions in these operating
instructions, will have to be observed!
Do not operate in ambient temperatures above those indicated on the
luminaire nameplate.
The luminaires shall be operated as intended and only in undamaged and
perfect conditions! And Keep tightly closed when in operation!
The technical data indicated on the luminaire are to be observed!
Change of the design and modifications to the luminaire are not permitted!
Multiple, short-term switching must be observed!
Only genuine Cooper Crouse-Hinds spare parts may be used for replacement!
!
2. Technical data
Enclosure specification
Material of enclosure: Aluminum alloy without Cu
Finish: Painted polyester power coating
Material of globe: Tempered glass
Mounting bracket: Stainless steel or Steel painted
Fasteners: All external fasteners stainless steel
Installation: Mounting bracket with aiming quadrant
Weight: 4.5Kg(Normal version)/6Kg(EM version)
Ambient temperature: -40ºC~+55ºC
Degree of protection: IP 66 acc. to EN60529/IEC60529
Entry specification
Indirect entry
: 2
×
M20
×
1.5 or 2
×
M25
×
1.5 cable entry. One entry
is fitted with an stopping plug.
Direct entry
: M25 or G3/4 cable entry.
Electrical specification
Wattage: 28W/46W/51W/63W/75W
Voltage: AC: 100V-240V 50/60Hz, DC: 108~250V
Lamp: LED Arrays
CRI: 70
Insulation class: I acc. to IEC60598
Terminals capacity: 3 core or 6 core conductor/cable
Solid: 0.5~6mm
2
, Flexible: 0.25~4mm
2
5. Installation
5.1 General
The respective national regulations as well as the
general rules of engineering which apply to the
installation and operation of apparatus will have to
be observed!
The improper installation and operation may result
in the invalidation of the guarantee.
5.2 Mounting luminaire
5.2.1 Mounting the bracket
Only use the accompanying mounting bracket!
Securely fasten the mounting bracket to a suitable
base with sufficient load-bearing capacity. The
mounting should be secured with M8 bolts and
relative lock washers, nuts should be used.
5.2.2 Adjustment of floodlight
The luminaire can be adjust and lock the luminaire to
30-degree intervals. The holes in the bracket gives
increments of 30 degree. Loosen the set screw and
fixing bolts to rotate the bracket to set the required
tilt angle.
4. Fields of Application
The Luminaire with a separate terminal box and IP66 sealing making it suitable for
use for The luminaire is designed for use areas in indoors and outdoors in Marine
and Wet locations, where moisture, dirt, corrosion, vibration and rough usage may
be present. Application ambient temperature is -40
ºC
~+55
ºC
. The enclosure
materials used, including any external metal parts, are High quality materials that
ensure a corrosion resistance and resistance to chemical substances according to
the requirements for use in a “normal“ industrial atmosphere. In case of use in an
extremely aggressive atmospheres, please refer to manufacture.
Re-tighten the set screw and fixing screws.
See Fig.1 for details
.
The minimum distance between the luminaire
and illuminated surface, directly in front of the
luminaire, is 0.5 meter. The lamp must not be
illuminated when at a distance of less than 0.5m
from inflammable material.
5.3 Cable entries/Blanking plugs
Unused holes must be closed with certified plug.
The cable glands and plugs should be certified
and sealing washer
(if required by manual of
cable gland/plug) must be used to obtain IP66.
The authoritative mounting guidelines for the
cable glands used must be observed. Mounting
the selected cable entries acc. type and
dimensions of the main connection cable
following their manufacturer instructions. The
cable temperatures are given as the rise over the
max. rated ambient (Tamb). This allows the user
to adjust the cable specification for actual
maximum site ambient.
Only heat resistant cable according to the data on
the type label may be used! The max. conductor
size is 4mm². The standard looping cable size is
4mm².
5.4 Opening/closing the luminaire
5.4.1 General
The opening of luminaire always shall be without
voltage! All gasket seals must be clean and
undamaged before closing the luminaire. Make
sure the luminaires is well closed before operation!
5.4.2 Terminal chamber cover
Unscrew the screws and remove the terminal
chamber cover. And carry out the steps in reverse
order to close the luminaire. Check all screws to
ensure a secure fit during operation (Torque for
screws: 1.5 Nm).
5.5 Electrical connection
The electrical connection of the lamp must only be
established by qualified electricians.
Make sure the supply voltage is the same as the
luminaire voltage!
1.
Dimensions
EM version/Indirect entry
Normal version/Indirect entry
Normal version/Direct entry
EM version/Direct entry