background image

7

Technical Data 

TD013014EN

Effective May 2021

Power Defense Insulated Case Circuit  

Breaker NRX NF and RF Renewal Parts 

  

EATON

 www.eaton.com

Table 12.  Mechanical interlock parts and kits

Catalog number

Description

N-Frame

R-Frame

Mechanical interlock kit, 2-way, drawout

NFMI2D

RFMI2D

Mechanical interlock kit, 3-way, type 31, drawout

NFMI31D

RFMI31D

Mechanical interlock kit, 3-way, type 32, drawout

NFMI32D

RFMI32D

Mechanical interlock kit, 3-way, type 33, drawout

NFMI33D

RFMI33D

Mechanical interlock kit, 2-way, fixed

NFMI2F

RFMI2F

Mechanical interlock kit, 3-way, type 31, fixed

NFMI31F

RFMI31F

Mechanical interlock kit, 3-way, type 32, fixed

NFMI32F

RFMI32F

Mechanical interlock kit, 3-way, type 33, fixed

NFMI33F

RFMI33F

Mechanical interlock cable 5 feet

NRXMIC5

NRXMIC5

Mechanical interlock cable 6 feet

NRXMIC6

NRXMIC6

Mechanical interlock cable 8 feet

NRXMIC8

NRXMIC8

Mechanical interlock cable 10 feet

NRXMIC10

NRKMIC10

ote:

N

Cable kit must be ordered separately .

Table 13.  PXR trip unit replacement kits and parts

Description

Catalog number

PXR25 LSIG/LSIA with ARMS and Modbus

PXR25V000LGAMK

PXR25 LSI with ARMS and Modbus

PXR25V00L0AMK

PXR20 LSIG/LSIA with ARMSs and Modbus

PXR20V000LGAMK

PXR20 LSIG/LSIA

PXR20V000LG0CK

PXR20 LSI

PXR20V000L00CK

PXR20 LSI with ARMS and Modbus

PXR20V000L0AMK

External PT module (required for PXR25 voltage metering)

NRXDTPTM

PXPM change current kit (license and labels)

PXPM-SW-PXRIN-KIT-1

Each In Programming Tool can be linked to only one breaker. Once linked, it has the capability of changing that one breaker’s continuous current rating, to 

any eligible rating, an unlimited number of times.

ote:

N

For more information, visit www .Eaton .com/PXPM .

Catalog number references

Symbol

Function/protection

L

Long time trip (overload)

S

Short time trip

I

Instantaneous trip

G

Ground (Earth) fault trip

A

Ground (Earth) Alarm only

Type 32 Mechanical interlock configuration

Type 33 Mechanical interlock configuration

Type 31 Mechanical interlock configuration

Summary of Contents for NRX NF

Page 1: ...nter field option kits 3 Padlockable pushbutton cover field option kits and clarification 4 Breaker key lock provision field option kits 4 Communication modules and accessories 5 Available front conne...

Page 2: ...ame Drawout PXR 2 blocks IZMX SEC TB2 W 1 IZMX SEC TB2 W 1 Drawout secondary terminal block kit PXR 12 blocks IZMX SEC TB12 W 1 IZMX SEC TB12 W 1 Fixed secondary terminal block kit PXR 2 blocks IZMX S...

Page 3: ...c IZMX SR230AD 1 IZMX SR230AD 1 24 Vdc IZMX SR24DC 1 IZMX SR24DC 1 48 Vdc IZMX SR48DC 1 IZMX SR48DC 1 60 Vdc IZMX SR60DC 1 IZMX SR60DC 1 Undervoltage release field option kits 110 127 Vac Vdc IZMX UVR...

Page 4: ...equired N frame R Frame Castell breaker mounted kit Cylinder CL1019 SPECIFY Modified to 90 deg key FKW6 NI NCASTELLKIT NCASTELLKIT CES breaker mounted kit Cylinder 5256 LAG CAM cylinder 5256 Direction...

Page 5: ...conductor extension 50 kA and below 50 NRXBUSEXT503 Bus conductor extension 65 kA and below 65 NRXBUSEXT653 2 Cable terminals two holes 65 Yes TA700NB1M With control wire provisions 65 Yes TA700NB1MCW...

Page 6: ...nnect phase barriers 4 NF 4RBAR Front connect phase barriers 3 NF 3FBAR Front connect phase barriers 4 NF 4FBAR Cassette interphase barrier kit 3 RF IZMX IB403 W 1 Cassette interphase barrier kit 4 RF...

Page 7: ...10 feet NRXMIC10 NRKMIC10 Note N Cable kit must be ordered separately Table 13 PXR trip unit replacement kits and parts Description Catalog number PXR25 LSIG LSIA with ARMS and Modbus PXR25V000LGAMK P...

Page 8: ...tio Appendix A Series NRX with Digitrip Table 15 Secondary terminal replacement parts blocks and kits Catalog number Description Kit contents N frame R frame Drawout secondary terminal block kit digit...

Page 9: ...or wiring internally to spring release LCS1 LCS1 Latch check with 1 Form C contact for remote indication LCS2 LCS2 Mechanical pop out trip indicator option kit no contacts MTKIT RFMTKIT Interlock mech...

Page 10: ...a NC1250T a 1600 NC1600T a a IEC only not UL listed b Not available with the 1150 trip unit Note N Rating plug must be selected based on breaker frame rating Table 19 Digitrip replacement kits and ac...

Page 11: ...figurations IL0131123EN NF Power Defense ICCB with PXR Type NF low voltage power air circuit breakers instruction manual MN013001EN NF Power Defense ICCB Installation Instructions for Pop Out Mechanic...

Page 12: ...ICCB with PXR Instructions for PT Module IL01301074E NF and RF Power Defense ICCB with PXR Instructions for Undervoltage Release Shunt Trip and Overcurrent Trip Switch IL0131087EN NF and RF Power Defe...

Reviews: