background image

3

Technical Data 

TD013014EN

Effective May 2021

Power Defense Insulated Case Circuit  

Breaker NRX NF and RF Renewal Parts 

  

EATON

 www.eaton.com

Table 2.  Cassette shutter field option kits

Field-installable option kit for drawout cassette for installation by customer .

Number 

of poles

Frame

Shutter kit catalog number

Three-pole

N-frame

SHTR3P

Four-pole

N-frame

SHTR4P

Three-pole

R-frame

RFSHTR3P

Four-pole

R-frame

RFSHTR4P

Table 3.  Power Defense ICCB breaker control replacement parts and kits

These parts are 

not compatible

 with the NRX with digitrip breakers . See 

Appendix A

 .

Catalog number

Description

Control voltage

N-frame

R-frame

Shunt trip field option kits 

a

110-127 Vac/Vdc

IZMX-ST110AD-1

IZMX-ST110AD-1

208-250 Vac/Vdc

IZMX-ST230AD-1

IZMX-ST230AD-1

24 Vdc

IZMX-ST24DC-1

IZMX-ST24DC-1

48 Vdc

IZMX-ST48DC-1

IZMX-ST48DC-1

60 Vdc

IZMX-ST60DC-1

IZMX-ST60DC-1

Motor operator field option kits

110-127 Vac/Vdc

IZMX-M16-110AD-1

IZMX-M40-110AD-1

208-250 Vac/Vdc

IZMX-M16-230AD-1

IZMX-M40-230AD-1

24 Vdc

IZMX-M16-24DC-1

IZMX-M40-24DC-1

48 Vdc

IZMX-M16-48DC-1

IZMX-M40-48DC-1

60 Vdc

IZMX-M16-60DC-1

IZMX-M40-60DC-1

Spring release device field option kits

110-127 Vac/Vdc

IZMX-SR110AD-1

IZMX-SR110AD-1

208-250 Vac/Vdc

IZMX-SR230AD-1

IZMX-SR230AD-1

24 Vdc

IZMX-SR24DC-1

IZMX-SR24DC-1

48 Vdc

IZMX-SR48DC-1

IZMX-SR48DC-1

60 Vdc

IZMX-SR60DC-1

IZMX-SR60DC-1

Undervoltage release field option kits

110-127 Vac/Vdc

IZMX-UVR110AD-1

IZMX-UVR110AD-1

208-250 Vac/Vdc

IZMX-UVR220AD-1

IZMX-UVR220AD-1

24 Vdc

IZMX-UVR24DC-1

IZMX-UVR24DC-1

48 Vdc

IZMX-UVR48DC-1

IZMX-UVR48DC-1

60 Vdc

IZMX-UVR60DC-1

IZMX-UVR60DC-1

Latch check switch for wiring internally to spring release

IZMX-LCS-SR-1

IZMX-LCS-SR-1

Latch check with 1 Form C contact for remote indication

IZMX-LCS-1

IZMX-LCS-1

Mechanical pop-out trip indicator option kit (no contacts)

MTKIT

RFMTKIT

Bell alarm/OTS contact field option kit (2 Form C contacts) 

IZMX-OTS16-1

IZMX-OTS40-1

Auxiliary switch, 2 form C contacts, short leads (5.5 ins)

IZMX-AS22-16-1

IZMX-AS22-16-1

Auxiliary switch, 2 form C contacts, long leads (9.5 ins)

IZMX-AS22-4O-1

Mechanical counter

NCOUNTERKIT

RCOUNTERKIT

Cell switch (left for NF, left or right for RF)

IZMX-CS16-1

IZMX-CS40-1

Shunt trips are rated for continuous duty

 

For use with breakers that have mechanical pop-out indicator option already installed.

ote:

N

All accessories include the required number of terminal blocks to install . See appendix B for a list of installation instruction document numbers that are 

available on eaton .com .

Cassette 

cell switch

Auxiliary switch

Latch check switch

Mechanical trip 

indicator

Latch check switch

Operations counter

Summary of Contents for NRX NF

Page 1: ...nter field option kits 3 Padlockable pushbutton cover field option kits and clarification 4 Breaker key lock provision field option kits 4 Communication modules and accessories 5 Available front conne...

Page 2: ...ame Drawout PXR 2 blocks IZMX SEC TB2 W 1 IZMX SEC TB2 W 1 Drawout secondary terminal block kit PXR 12 blocks IZMX SEC TB12 W 1 IZMX SEC TB12 W 1 Fixed secondary terminal block kit PXR 2 blocks IZMX S...

Page 3: ...c IZMX SR230AD 1 IZMX SR230AD 1 24 Vdc IZMX SR24DC 1 IZMX SR24DC 1 48 Vdc IZMX SR48DC 1 IZMX SR48DC 1 60 Vdc IZMX SR60DC 1 IZMX SR60DC 1 Undervoltage release field option kits 110 127 Vac Vdc IZMX UVR...

Page 4: ...equired N frame R Frame Castell breaker mounted kit Cylinder CL1019 SPECIFY Modified to 90 deg key FKW6 NI NCASTELLKIT NCASTELLKIT CES breaker mounted kit Cylinder 5256 LAG CAM cylinder 5256 Direction...

Page 5: ...conductor extension 50 kA and below 50 NRXBUSEXT503 Bus conductor extension 65 kA and below 65 NRXBUSEXT653 2 Cable terminals two holes 65 Yes TA700NB1M With control wire provisions 65 Yes TA700NB1MCW...

Page 6: ...nnect phase barriers 4 NF 4RBAR Front connect phase barriers 3 NF 3FBAR Front connect phase barriers 4 NF 4FBAR Cassette interphase barrier kit 3 RF IZMX IB403 W 1 Cassette interphase barrier kit 4 RF...

Page 7: ...10 feet NRXMIC10 NRKMIC10 Note N Cable kit must be ordered separately Table 13 PXR trip unit replacement kits and parts Description Catalog number PXR25 LSIG LSIA with ARMS and Modbus PXR25V000LGAMK P...

Page 8: ...tio Appendix A Series NRX with Digitrip Table 15 Secondary terminal replacement parts blocks and kits Catalog number Description Kit contents N frame R frame Drawout secondary terminal block kit digit...

Page 9: ...or wiring internally to spring release LCS1 LCS1 Latch check with 1 Form C contact for remote indication LCS2 LCS2 Mechanical pop out trip indicator option kit no contacts MTKIT RFMTKIT Interlock mech...

Page 10: ...a NC1250T a 1600 NC1600T a a IEC only not UL listed b Not available with the 1150 trip unit Note N Rating plug must be selected based on breaker frame rating Table 19 Digitrip replacement kits and ac...

Page 11: ...figurations IL0131123EN NF Power Defense ICCB with PXR Type NF low voltage power air circuit breakers instruction manual MN013001EN NF Power Defense ICCB Installation Instructions for Pop Out Mechanic...

Page 12: ...ICCB with PXR Instructions for PT Module IL01301074E NF and RF Power Defense ICCB with PXR Instructions for Undervoltage Release Shunt Trip and Overcurrent Trip Switch IL0131087EN NF and RF Power Defe...

Reviews: